state may happen.

Q. When a fire wall is in a network, can you install DX-VS1UE and can operate it?

A. In order for DX-VS1UE to transmit data and a picture, the default port number of 80th and 8080th needs to be vacant.

However, usually only the 80th port is vacant in the network with a fire wall because of se- curity. In this case, a user can change a picture transmission port into the other port which can pass fire walls from 8080th.

A user can set up on Customizing Page of Server Configuration Page.

Q. How can a user monitor the image transmitted from DX-VS1UE?

A. A user can see the real-time image of DX-VS1UE using 5 or later versions of Internet Explorer. It is necessary to install the DX-VS1UE ActiveX control for Internet Explorer at this time. This ActiveX control is used on the page (Simple Viewer Page, DVR Configura- tion Page, Pan/tilt/zoom Control Page, etc.) where a user monitors an image.

When the ActiveX (DX-VS1UE Control) is already installed, it can delete and install.

Q. If the ActiveX is not installed properly, what should I do?

A. Depending on the kind of computer, the ActiveX Control (the DX-VS1UE control pro- gram) may not be installed appropriately. In this case, Any image cannot be seen or a mes- sage “No input” is displayed. In order to solve this problem, please remove the DX-VS1UE control program as follows, and re-install.

The DX-VS1UE control program is installed in C:\windows\Downloaded Program Files in case of Windows 98 or Windows Me. In case of Windows NT or Windows 2000, it is in- stalled in C:\winnt\Downloaded Program Files.

Please put the mouse cursor on the DX-VS1UE control program, click the right button, and choose remove menu.

When you access DX-VS1UE once again, the DX-VS1UE control program will be in- stalled.

Q. When the ActiveX causes an error at the time of execution, how can I solve the prob- lem?

A1. In case a message box like “Mismatched Version” is displayed, please do the following.

The ActiveX in DX-VS1UE is re-installed.

A2. In case a message box like “DX-VS1UE client initializing failed” is displayed, please do the following.

The Winsock2 library is not installed. The Winsock2 library for Windows 95/98 can be downloaded from a public site. Please install Winsock2 in your system after download, and restart your browser.

Q. The image of DX-VS1UE is not displayed. What is the problem?

A. There is the possiblility that BNC cable is not connected appropriately. If the cable is connected appropriately, connection of DX-VS1UE and an external Pan/tilt/zoom camera may be unstable. Please check the connection of the BNC cable, or whether the BNC cable

35

DX-VS1UE User’s Manual

Image 36
Contents DX-VS1 Table of Contents DX-VS1UE User’s Manual What is DX-VS1UE? FeaturesFor PC to access DX-VS1UE For DX-VS1UEConfirmation of the Accessories Description Amount RemarksFront View and Description Connector Remarks DX-VS1UE View and DescriptionRear View and Description Connector name Remarks PTZ/DVR/COMDescription of DIP Switches LEDs of Ethernet portRight-hand side DIP swith is not available Installation Summary ・Connecting DX-VS1UE with PCDX-VS1UE User’s Manual DX-VS1UE User’s Manual ・The circuit diagram of a sensor terminal Installing DX-VS1UE Setup Program Assigning IP Address and setting Administrator Condition・Setting Administrator Conditions MAC Address Media Access Control AddressIP Address Crossover CableConnecting a digital recorder to DX-VS1UE Connecting BNC cableConnecting RS-232C cable PTZ/DVR/CO Starting Web browser Composition of a screenDVR Mail Event Configuration Application ConfigurationCheck E-Mail Options Check Points for E-mail Sending Problem FTP directory configurationFTP event configuration Pan/tilt/zoom ConfigurationTransmission Performance of E-mail and FTP Select Serial PortNew Preset New GroupMode Configuration Serial Port Configuration Manual SettingSerial Port Selection Select Attached DevicePTZ Command for Manual Script Alarm Parameters for E-mail / FTP Application Device Type for Input PortsCurrent State for Input Ports Motion Detection ThresholdAlarm Preset Web Server TCP PortVideo Server TCP Port CustomizingWhen the changed settings are reflected? Login Page EditingDetailed Specifications of DX-VS1UE HardwareVideo and Compression NetworkMisc functions and I/O Serial connection with digital recorder Frequently Asked Questions Installation and operation of DX-VS1UE DX-VS1UE User’s Manual DX-VS1UE User’s Manual DX-VS1UE User’s Manual