PTZ Command for Manual Script

1. Escape Characters

#Special command

@Hexadecimal character

% Decimal character

^Character

,Break character

;End of current packet

& Special operation

2. Special command (Followed by #)

A

Address assigned by pan/tilt/zoom configuration

XAcceleration rate selected by user

Sx Checksum calculation method

x = 0 Sum of entire frame, size = 1byte x = 1 Sum of entire frame, size = 2byte

x = 2 Sum of entire frame except first byte(sync), size = 1byte

x = 3 Sum of entire frame except first byte(STX) and last byte(ETX), size = 1byte

x = 4 Sum and one's complement of entire frame except first byte(STX) and last byte(ETX), size = 1byte

x = 5 XOR sum of entire frame, size = 1byte x = 6 XOR sum of entire frame, size = 2byte

x = 7 XOR sum of entire frame except first byte(sync), size = 1byte

x = 8 XOR sum of entire frame except first byte(STX) and last byte(ETX), size = 1byte

x = 9 XOR sum and one's complement of entire frame except first byte(STX) and last byte(ETX), size = 1byte

3. Special Operation (Followed by &)

Sx Delay about ( ([acceleration rate] + 1) * (100 * x) ) ms

x0 ~ 4

4. Exceptions

Normal character following Escape Sequence, must use break character for identifying the end of sequence

*Some protocols are not to be made command script with above method. It is because they use another method of checksum calculation.

26

DX-VS1UE User’s Manual

Image 27
Contents DX-VS1 Table of Contents DX-VS1UE User’s Manual Features What is DX-VS1UE?For DX-VS1UE For PC to access DX-VS1UEDescription Amount Remarks Confirmation of the AccessoriesDX-VS1UE View and Description Front View and Description Connector RemarksPTZ/DVR/COM Rear View and Description Connector name RemarksLEDs of Ethernet port Description of DIP SwitchesRight-hand side DIP swith is not available ・Connecting DX-VS1UE with PC Installation SummaryDX-VS1UE User’s Manual DX-VS1UE User’s Manual ・The circuit diagram of a sensor terminal Assigning IP Address and setting Administrator Condition Installing DX-VS1UE Setup ProgramCrossover Cable ・Setting Administrator ConditionsMAC Address Media Access Control Address IP AddressConnecting a digital recorder to DX-VS1UE Connecting BNC cableConnecting RS-232C cable PTZ/DVR/CO Composition of a screen Starting Web browserDVR Mail Event Configuration Application ConfigurationCheck E-Mail Options FTP directory configuration Check Points for E-mail Sending ProblemSelect Serial Port FTP event configurationPan/tilt/zoom Configuration Transmission Performance of E-mail and FTPNew Group New PresetMode Configuration Select Attached Device Serial Port ConfigurationManual Setting Serial Port SelectionPTZ Command for Manual Script Motion Detection Threshold Alarm Parameters for E-mail / FTP ApplicationDevice Type for Input Ports Current State for Input PortsCustomizing Alarm PresetWeb Server TCP Port Video Server TCP PortLogin Page Editing When the changed settings are reflected?Network Detailed Specifications of DX-VS1UEHardware Video and CompressionMisc functions and I/O Serial connection with digital recorder Frequently Asked Questions Installation and operation of DX-VS1UE DX-VS1UE User’s Manual DX-VS1UE User’s Manual DX-VS1UE User’s Manual