Non-Pixel Defects

Bright Line Defects

Polarizer Scratch, Lint

Contamination

Qty Allowed

 

 

Size

 

Separation

 

 

 

Defect Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

L > 0.120”

-

 

 

 

 

 

 

 

 

 

 

W > .010”

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.020” < L < .120”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

.002” < W < .010”

 

.100”

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not cause for

 

L< .020”

 

 

 

 

 

 

 

 

 

 

rejection

 

W< .002”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: A bright spot is a subpixel which, when a black screen is being displayed, is visible through a 20% transmission ND filter to an unaided eye at least 45 cm [18”] away from the display surface in a dark room. Dark spots in which the dark spot area divided by the subpixel area is less than 1/3 are not counted.

8.0Regulatory Agency Requirements

8.1Safety Certification

The Monitor does not inhibit customer from certifying product to following safety standards:

UL 1950/CAN/CSA C22.2 No. 950-95 Safety of Information Technology, including electrical business equipment

UL 291Standard for Automated Teller Machine

EN 60950 Safety of Information Technology, including electrical business equipment.

8.2CE Marking (Declaration according to ISO/IEC Guide 22 and EN45014)

The Monitor does not inhibit customer from conforming to the following EC Directives:

Council Directive 73/23/EEC and 93/68/EEC (Latest Amendment) on the harmonization of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits is based on compliance with the following harmonized standards:

EN 60950 June 2000

EN 41003:1991

Council Directive 89/336/EEC, 92/31/EEC and 93/68/EEC (Latest Amendment) on the approximation of the laws of the Member States relating to electromagnetic compatibility is based on compliance with the following harmonized standards:

Electromagnetic Emissions

EN 55022 Class A: 1994

 

Title: Product Specification: LC12 High-Bright Monitor

Page 19 of 24

Document Number: 023-0284-01

 

Revision: A

Image 19
Contents LC12 High-Bright Monitor Table of Contents Design Workload Critical Failures Failure Definition 262,144 IntroductionBasic Construction Page Tair @ 60C Hours EnvironmentalTair @ HoursNon-operating random Sweep for 15 minutes, three axes, x, y, zFollowing exposure unit shall meet all Performance requirementsBlue video return Video Signal Input RequirementsVideo Signal Connector Pin Number Assignments Red video returnOvershoot High POS Steady Level Horizonta Vertical Video Mode Definitions Color Display DetectionBorder Timing and Frequency Video, Horizontal And Vertical Sync Vertical SyncPeriod Resolution 640x400 640x480 800x600 1024x768 Video ClockHorizontal Scan Freq Horizontal LineVideo Modes Most Negative Input Voltage DC Power Input RequirementsDC Power Input Lines Most Positive Input VoltageDisplay Performance Room Ambient Contrast Display Cosmetics Regulatory Agency Requirements ∙ Electromagnetic Immunity ReliabilityDescription of Warranty Glossary of Terms and Abbreviations Support and servicePage REV Date Description of Change Revision History