Planar LC12 manual Environmental, Tair @ 60C Hours, Tair @ 54C

Page 7

3.0Environmental

3.1Temperature and Humidity

The Monitor withstands operating and storage environmental conditions listed in Table 1.

 

General Operating

Shipping and Storage

Comments

 

0oC to 60oC

?-20oC to 60oC

 

Temperature

[32oF to 140oF]

[?-4oF to 140oF]

Note 2,3,4,5

 

 

 

Without

Relative Humidity

Note 1,4

Note 1

Condensation

Table 1. Temperature / Humidity Limits.

Tair is defined as ambient air temperature surrounding Monitor.

Note 1:

Tair < 32°C

: 95% RH maximum.

 

Tair > 32°C

: Absolute humidity content not to exceed 100% at 32oC.

Note 2:

Tair @

-20°C

< 48 hours

 

Tair @

60°C

< 168 hours

Note 3: Slight background color changes are allowed depending on ambient temperature. This phenomenon is reversible.

Note 4: Tair @

-30°C

: 15% RH (exterior face of Vandal Shield)

Tair @

54°C

: 100% RH (exterior face of Vandal Shield)

Note 5: Upper operating temperature limit of 60°C is without solar loading. See section 3.2 for operating temperature conditions with solar load.

Reference to "room ambient" is interpreted as 20°C - 25°C [68°F -?77°F] and applies throughout this specification unless otherwise noted.

Excluding the exterior face temperature range of the Vandal Shield (Note 4), this Monitor will not be subjected to environments outside of the limits of Table 1.

For product reliability predictions, the assumed temperature profile is:

Operating Time

Temperature

5%

0°C [32°F]

90%

30°C [86°F]

5%

60°C [140°F]

3.2Solar Loading

The Monitor is useable in an environment consisting of a 50 o C ambient air temperature and the following input solar power.

Title: Product Specification: LC12 High-Bright Monitor

Page 7 of 24

Document Number: 023-0284-01

Revision: A

Image 7
Contents LC12 High-Bright Monitor Table of Contents Design Workload Critical Failures Failure Definition 262,144 IntroductionBasic Construction Page Tair @ 60C Hours EnvironmentalTair @ HoursNon-operating random Sweep for 15 minutes, three axes, x, y, zFollowing exposure unit shall meet all Performance requirementsBlue video return Video Signal Input RequirementsVideo Signal Connector Pin Number Assignments Red video returnOvershoot High POS Steady Level Horizonta Vertical Video Mode Definitions Color Display DetectionBorder Timing and Frequency Video, Horizontal And Vertical Sync Vertical SyncPeriod Resolution 640x400 640x480 800x600 1024x768 Video ClockHorizontal Scan Freq Horizontal LineVideo Modes Most Negative Input Voltage DC Power Input RequirementsDC Power Input Lines Most Positive Input VoltageDisplay Performance Room Ambient Contrast Display Cosmetics Regulatory Agency Requirements ∙ Electromagnetic Immunity ReliabilityDescription of Warranty Glossary of Terms and Abbreviations Support and servicePage REV Date Description of Change Revision History