2.0Basic Construction
2.1Weight
Monitor weight does not exceed 5 Kgs (11 lbs).
2.2Mechanical Mounting Requirements
Per Planar Mechanical Outline drawing
2.3Monitor Electronics
Electronic components requiring heat sinks are installed independent of the Monitor enclosure. That is, its sheet metal chassis is not used as a heat sink for any electronic component.
2.4Cooling Fan
Cooling fans are installed to maintain appropriate internal operating temperatures when the Monitor is subjected to its operating environment of Section 3. Forced air convection is used to cool the LCD Panel (front and back).
2.5Vandal Glass
The Monitor is designed to operate with a vandal glass 289 mm x212 mm x 10 mm in place. This vandal glass in not provided with the Monitor.
2.6Air Filtration
An air filter mesh is included to prevent ingress of insects and ensure continual flow of cooling air within the Monitor. The air filter mesh is externally accessible for cleaning.
2.7Connectors
There are two (2) connectors supplied as an integral part of the Monitor.
2.7.1Video Signal Connector
The Monitor unit includes a chassis mounted
2.7.2DC Power Input Connector
The DC power input connector is a chassis mounted
Title: Product Specification: LC12 | Page 5 of 24 |
Document Number: | Revision: A |