Planar PD8130, PD8150 operation manual Operation

Page 75

Operation

Lamp Hour Reset: When you replace the projector lamp (refer to Lamp Replacement on page 63), you should also reset the lamp hour counter. To do this, select Lamp Hour Reset from the Service menu, then press ENTER. Press ENTER again to confirm the reset. Or, to cancel the operation, press on the remote to highlight No, then press ENTER.

Note

WARNING

Reset the Lamp Hour counter ONLY after you replace the lamp. Otherwise, the reported “Lamp Hours” will be inaccurate.

Do not exceed the recommended lamp life. An old lamp becomes increasingly fragile and prone to sudden failure.

Factory Reset: Select Factory Reset from the Service menu to restore all projector settings – except those listed below – to their factory-default values:

Lamp Hours

User Memory 1 / User Memory 2

ISF Day

ISF Night

Model Name / Serial Number

Language

Blue Only: This feature removes all red and green color information from the image, and is useful for color-calibrating the projector or other video components.

Test Patterns: The PD8130/PD8150 has numerous internal test patterns that are useful to technicians for advanced calibration, measurement and fault isolation purposes. To access them, select Test Patterns from the Service menu and set it to On.

The available test patterns are:

White

Black

Red

Green

Blue

Cyan

Magenta

Yellow

ANSI Checkerboard

Horizontal Gray Ramp

Focus Grid

Press or on the remote control unit or built-in keypad to cycle through the test patterns.

Planar PD8130/PD8150 Installation/Operation Manual

61

Image 75
Contents PD8130 PD8150 Home Theater Projector Page For Projectors, Video Processors and Controllers TWO Year Limited WarrantyContact a Planar Authorized Service Center to Obtain Service Additional Information Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part Table of Contents Operation Maintenance and TroubleshootingSpecifications Table of Contents Xii List Of Figures List Of Figures Xiv Introduction About This ManualTarget Audience If you need Turn to Using This ManualDescription, Features and Benefits Additional Features of the PD8150Key Features and Benefits Optional Accessories Parts ListControls and Functions PD8130/PD8150 at a GlanceCursor Keys Exhaust Vent PD8130/PD8150 Rear/Bottom/Top View Rear Cover RGB Power Input 100 to 240 VACComponent 1/SCART RCA connectors PD8130/PD8150 Rear PanelRS-232 Trigger 2 3.5-mm, mini phono jack PD8150 onlyPD8130/PD8150 Remote Control OFFSource Selection Buttons Brightness Memory Preset Buttons M1 / M2 / M3Picture Adjustment Buttons Contrast Aspect Ratio Selection ButtonInstallation Remote ControlOperation IR Reception Angles Quick Setup Installation OverviewStep Procedure For Details, Refer to Considerations InstallationProjector Installation Options Installation TypeAmbient Light Throw DistanceEstimating Throw Distance Vertical and Horizontal PositionVertical Lens Shift Vertical lens shift figures are for ceiling mount Horizontal Lens Shift Example OnlyFolded Optics Folded OpticsMounting the PD8130/PD8150 Connections to the PD8130/PD8150 Connector Panel AccessHDMI/DVI Connections See Figure Connecting Source Components to the PD8130/PD8150RGB Connections Component Video Connections 10. Composite and S-Video Connections RS-232 Controller ConnectionCommunications on Theater Equipment Connecting 12-VoltConnecting an External IR Trigger Output to ExternalConnecting to AC Power Turning on the Power Changing the OSD LanguageAdjusting the Picture Lens AdjustmentsOrientation Installation Installation Selecting An Input Source OperationSelecting Video Memory Selecting an Aspect RatioMain Using Picture-In-Picture PIPAvailable Main and PIP Source Combinations PIP Input SourceUsing the On-Screen Menus System ServiceMain AdvancedPD8130/PD8150 Main Menu Aspect Ratio Settings Aspect Geometry of Projected Image169 Letterbox 1080i Hdtv Image Sub-menu You must enter a passcode to access the Save ISFTypical Pluge Pattern for Adjusting Brightness Typical Test Pattern for Adjusting Sharpness Operation Overscan Examples CropSource Select Sub-Menu PD8130/PD8150 Advanced Menu AdvancedOperation Color X/y Color Gamut ValuesRGB Adjust Sub-Menu 10. Fine Sync Sub-Menu Adjust the Phase after adjusting Tracking see below. If 11. PD8130/PD8150 System Menu System12. Source Enable Sub-Menu PBP1 PBP2 14. PIP Split-Screen Mode Control Operation Language 15. PD8130/PD8150 Service Menu ServiceOperation OSD menus are not available when in test pattern Lamp Replacement Maintenance and TroubleshootingLight and Enter Troubleshooting TipsTroubleshooting Chart Symptom Possible Causes SolutionLED is flashing red Maintenance and Troubleshooting Serial Communications Key CommandsRS232 Remote Button IR Code Description Keyname Set Serial Command Key Names and IR CodesGam.brig Operations Control Commands Function Action on unit Operations CommandsValues Serial CommandsSave.isf Source.sel = ? Bcolor = ? Auto.pow.off = ? M1.key = ? Act.source Language = ? Specifications PD8130/PD8150 SpecificationsPD8130/PD8150 Specifications Aspect Ratios Native ResolutionPerformance MicrodisplayUniversal Power Supply DimensionsWeight without lens Operating TemperaturePD8130/PD8150 Dimensions PD8130/PD8150 DimensionsSupported Timings Supported Signal Timings by InputPAL-B/G Page Part No -0858-00 rev. a January