ON SCREEN MESSAGE
Use the list below to check the message displayed on the screen.
Message | Meaning | Remedy |
NO SIGNAL | No input signal. | Properly connect the cables. |
REPLACE LAMP! | The lamp has reached the end of its life. | Replace the lamp and reset lamp life. |
|
|
|
OUT OF RANGE | Improper signal feed to the projector. | Adjust resolution, V(Hz) : refresh rate of the |
| equipment, referring to the Timing Chart. | |
|
| |
|
|
|
ENGLISH
SPECIFICATIONS
❖Optical characteristics
Panel | 0.8 inch 16:9 |
| 1280 x 720 pixels |
| Digital Micromirror DeviceTM |
Lamp | Super High Pressure 150W |
Lens | f: 26.5 to 30.7 / F: 3.0 |
Projection size | 40 to 250 inches |
Light output | 700 ANSI LUMEN typical |
❖Input/Output
VIDEO IN | RCA x 1 |
| |
| Composite video |
| |
| |
COMPONENT IN | RCA x 3 |
| Y, CB/PB, CR/PR |
RGB/HD IN | |
| Analog RGB |
| HD:1080i, 720p, 480p |
| T.M.D.S compliant (single link only) |
| ☞ P.34 |
REMOTE CONTROLLER IN
Mini jack type x 1
REMOTE CONTROLLER OUT
Mini jack type x 1
AC IN | 3 Prong Grounding Type |
TRIG.1 OUT, TRIG.2 OUT | |
| Mini Jack x 2 |
| Output: DC12V or 0V |
RS232C | RS232C receptacle plug x 1 |
❖ General
Power requirement | AC |
Power consumption | < 250 W |
Standby consumption | < 3.3 W |
Chassis isolation | |
Safety | UL6500 |
| CSA E60065 |
| EN60950 |
EMC | FCC |
| EN55022 |
Dimensions | 15 15/16(W) x 18 9/16(D) x 6 1/8(H) inch |
| 404.5(W) x 471(D) x 158(H) mm |
Net weight | 13 kg |
Operating Temperature | 5 to 35 °C |
Operating humidity | 30 to 85% |
Storage Temperature | – 20 to 60 °C |
Storage humidity | 30 to 85% |
❖Accessories
•Lens cap x 1
•Remote controller x 1
•Batteries x 2
•AC power code (only for 125V) x 1
•User Guide x 1
•Control Adapter cable (Mini jack to RCA) x 1
•Warranty Card (1 copy each for USA, CANADA)
Specifications may be subjected to change without any prior notice.
33