JVC GD-V502PCE manual Off

Page 11

Basic Controls

Stand-by (ON/OFF) button

The Plasma Display must first be plugged into the wall outlet and turned on at the power switch (see page 12). Press this button to turn the Plasma Display On, from Stanby mode. Press it again to turn the Plasma Display Off to Stanby mode.

SURROUND button

On

Off

The benefits of surround sound are enormous. You can be

 

 

 

 

 

 

 

 

 

 

completely enveloped in sound; just as if you were at a

 

 

 

 

 

concert hall or cinema.

 

 

 

 

 

The surround setting switches on and off each time the

 

 

 

 

 

SURROUND button is pressed.

 

Surround

On

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

The surround settings are memorized separately for

each Sound mode (Normal, Auto).

 

 

 

 

INPUT button

 

 

 

 

 

 

 

(INPUT1, INPUT2, INPUT3 and PC IN Selection)

 

 

 

 

Press to select INPUT1, INPUT2, INPUT3 and PC IN input

 

 

 

 

SLOTS sequentially. (see page 13)

 

 

 

 

 

INPUT

Sound mute On/Off (see page 20)

 

 

 

 

 

 

 

 

 

 

 

SURROUND

 

Volume Adjustment

 

 

 

 

 

Press the Volume Up “+” or Down “–” button to increase or

 

 

 

 

 

 

 

 

decrease the sound volume level.

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

R button (see page 14-15)

 

 

 

N

 

 

R

Press the R button to return to previous menu screen.

 

 

 

 

ACTION button

 

 

 

 

 

 

 

Press to make selections.

 

 

 

 

 

 

 

POSITION buttons

 

Digital Zoom (see page 21)

 

 

 

 

SOUND button (see page 20)

 

 

 

 

ZOOM

Press to access

 

 

 

 

Press to adjust the SOUND.

 

MOVE

 

 

 

 

 

 

 

 

PICTURE

SOUND

SET UP

 

 

 

 

Digital Zoom.

 

 

 

 

SET UP button

 

This displays an enlargement

 

 

 

 

(see page 14-15)

 

 

 

 

 

 

of the designated part of the

MULTI

 

 

ZOOM

 

 

 

 

 

 

 

 

displayed image.

PIP

SWAP

SELECT MOVE

 

 

 

 

 

 

 

PICTURE POS./SIZE button

 

 

PICTURE

 

 

ASPECT

(see page 17)

 

 

 

POS. /SIZE

 

 

 

 

 

 

 

 

 

 

 

ASPECT button

 

 

 

 

 

 

 

Press to adjust the aspect.

 

 

 

 

 

 

 

(see page 16)

 

 

 

PC

 

 

OFF TIMER

 

 

 

 

 

 

 

 

 

OFF TIMER button

 

 

 

 

 

 

 

The Plasma Display can be preset to switch to stand-by after a

 

 

 

 

fixed period. The setting changes to 30 minutes, 60 minutes, 90

 

 

 

 

minutes and 0 minutes (off timer cancelled) each time the button is

PLASMA DISPLAY

pressed.

30

60

90

 

 

 

 

 

 

 

 

 

PC button

 

 

 

 

 

0

 

 

 

 

 

 

When three minutes remain, “Off timer 3” will flash.

Press the “PC” input mode selection button to select the

PC input mode.

 

 

 

The off timer is cancelled if a power interruption occurs.

This button is used to switch directly to PC input mode.

 

 

 

 

Note:

In 2 screen display, the same input mode cannot be selected for the main picture and sub picture.

11

Image 11
Contents Plasma Display Monitor GD-V502PCEINSTRUCTIONS Table of Contents Green-and-Yellow Earth Important Safety NoticeFor Your SAFETY, Please Read the Following Text Carefully This Apparatus Must be EarthedWhen using the Plasma Display Safety PrecautionsSetup Electric shocks can result if this is not done Cleaning and maintenanceIf problems occur during use Remote Control Batteries AccessoriesAccessories Supply AC cord fixing ConnectionsSpeakers SDA HD/SYNC SCL Signal Names for mini D-sub 15P ConnectorGND Ground Signal Name PC Input Terminals connectionCommunication parameters Installing the ferrite core Large sizeCommand Serial Terminals connectionBasic Controls Off Connecting the AC plug to the Wall Outlet Power On/Off and input signal selectionPower On/Off Power Indicator Remote Control SensorEnglishus Select the input signalSelecting the On-Screen Menu Language INPUT1 INPUT2 INPUT3On-Screen Menu Displays Press to Set up Press to access each adjust screen From the unitPress to Setup To setup Multidisplay screenJust Mode Picture ExplanationAspect Controls ZoomPos Adjusting Picture Pos./SizeAdjusting screen Helpful Hint N / Normalise NormalisationCinema Picture AdjustmentsNormal DynamicAGC Advanced settingsMute Sound AdjustmentSelect the magnification required for the enlarged display Digital ZoomDisplay the Operation Guide Select the area of the image to be enlargedPresent Time Present Time Setup / Set up TimerPresent Time Setup Press to exit from Present Time SetupDisplay the Set up Timer screen Press to select Set up TimerReversal / Scroll selection Mode selectionStart setting Screensaver For preventing after-imagesPress to select Screensaver Setup of Screensaver TimeReduces screen after-image This function may be applicable to the non-picture area Side Panel AdjustmentINPUT3/VIDEO3/COMPONENT3/RGB3/PC3/DVD3/CATV3/VCR3/STB3 Reduces power consumptionCustomizing the Input labels How to Setup Multi Display Setup for Multi DisplayNTSC, PAL, Secam Press to select 2 ⋅ 2, 3 ⋅RGB Setup for Input SignalsComponent/RGB-in Select 3D Y/C Filter For Ntsc AV imagesPAL Secam Ntsc Colour system / Aspect AutoCinema reality If the picture image becomes unstableDisplays the H Horizontal/V Vertical frequencies Setting RGB sync signalSync Freq. kHz/V-Freq. HzPlasma Display panel Symptoms Check TroubleshootingApplicable input signals for PC Input Mini D-sub 15P ∗ Mark Input signal can be displayedGD-V502PCE SpecificationsGD-V502PCE Plasma Display Monitor