JVC GD-V502PCE manual Serial Terminals connection, Installing the ferrite core Large size, Command

Page 9

Connections

SERIAL Terminals connection

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

RS-232C

Ferrite core

 

(large size)

 

SERIAL

Straight cable

(supplied)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-sub 9p

Less than

3" 15/16

 

 

(10 cm)

Notes:

(1)Use the RS-232C cable to connect the computer to the Plasma Display.

(2)The computer shown is for example purposes only.

(3)Additional equipment and cables shown are not supplied with this set.

6 7 8 9

1 2 3 4 5

Pin layout for RS-232C

Installing the ferrite core (Large size)

Open

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details.

Communication parameters

Signal level

RS-232C compliant

 

 

Synchronization method

Asynchronous

 

 

Baud rate

9600 bps

 

 

Parity

None

 

 

Character length

8 bits

 

 

Stop bit

1 bit

 

 

Flow control

-

 

 

 

RS-232C Conversion cable

D-sub 9-pin female

Details

 

2

R X D

 

3

T X D

 

5

GND

4

6

Non use

 

7

Shorted

 

8

 

 

1

9

NC

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX

 

 

 

 

Colon

 

 

Parameter(s)

 

End

 

 

 

 

 

 

Start

 

3-character

(1 - 5 bytes)

 

(03h)

 

 

(02h)

 

command (3 bytes)

 

 

 

Notes:

(1)If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

(2)If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

 

Audio mute OFF

AMT

0

1

Audio mute ON

 

IMS

None

Input select (toggle)

 

SL1

Slot1 input

 

SL2

Slot2 input

 

SL3

Slot3 input

 

PC1

PC input

DAM

None

Screen mode select (toggle)

 

NORM

4 : 3

 

ZOOM

Zoom

 

FULL

16 : 9

 

JUST

Just

 

SELF

Auto

With the power off, this display responds to PON command only.

9

Image 9
Contents Plasma Display Monitor GD-V502PCEINSTRUCTIONS Table of Contents For Your SAFETY, Please Read the Following Text Carefully Important Safety NoticeThis Apparatus Must be Earthed Green-and-Yellow EarthSafety Precautions SetupWhen using the Plasma Display Cleaning and maintenance If problems occur during useElectric shocks can result if this is not done Accessories Accessories SupplyRemote Control Batteries Connections SpeakersAC cord fixing GND Ground Signal Name Signal Names for mini D-sub 15P ConnectorPC Input Terminals connection SDA HD/SYNC SCLCommand Installing the ferrite core Large sizeSerial Terminals connection Communication parametersBasic Controls Off Power On/Off Power On/Off and input signal selectionPower Indicator Remote Control Sensor Connecting the AC plug to the Wall OutletSelecting the On-Screen Menu Language Select the input signalINPUT1 INPUT2 INPUT3 EnglishusOn-Screen Menu Displays Press to Setup Press to access each adjust screen From the unitTo setup Multidisplay screen Press to Set upAspect Controls Mode Picture ExplanationZoom JustAdjusting screen Adjusting Picture Pos./SizeHelpful Hint N / Normalise Normalisation PosNormal Picture AdjustmentsDynamic CinemaAGC Advanced settingsMute Sound AdjustmentDisplay the Operation Guide Digital ZoomSelect the area of the image to be enlarged Select the magnification required for the enlarged displayPresent Time Setup Present Time Setup / Set up TimerPress to exit from Present Time Setup Present TimeDisplay the Set up Timer screen Press to select Set up TimerStart setting Mode selectionScreensaver For preventing after-images Reversal / Scroll selectionSetup of Screensaver Time Reduces screen after-imagePress to select Screensaver This function may be applicable to the non-picture area Side Panel AdjustmentReduces power consumption Customizing the Input labelsINPUT3/VIDEO3/COMPONENT3/RGB3/PC3/DVD3/CATV3/VCR3/STB3 How to Setup Multi Display Setup for Multi DisplayNTSC, PAL, Secam Press to select 2 ⋅ 2, 3 ⋅Component/RGB-in Select Setup for Input Signals3D Y/C Filter For Ntsc AV images RGBCinema reality Colour system / Aspect AutoIf the picture image becomes unstable PAL Secam NtscSync Setting RGB sync signalFreq. kHz/V-Freq. Hz Displays the H Horizontal/V Vertical frequenciesPlasma Display panel Symptoms Check TroubleshootingApplicable input signals for PC Input Mini D-sub 15P ∗ Mark Input signal can be displayedGD-V502PCE SpecificationsGD-V502PCE Plasma Display Monitor