JVC GD-V502PCE Important Safety Notice, For Your SAFETY, Please Read the Following Text Carefully

Page 3

Important Safety Notice

WARNING:

1)To prevent damage which may result in fire or shock hazard, do not expose this appliance to rain or moisture.

Do not place containers with water (flower vase, cups, cosmetics, etc.) above the set. (including on shelves above, etc.)

2)To prevent electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.

3)Do not remove the earthing pin on the power plug. This apparatus is equipped with a three pin earthing-type power plug. This plug will only fit an earthing-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact an electrician.

Do not defeat the purpose of the earthing plug.

4)This is a class A product. In a domestic environment this product may cause radio interference in which case you may be required to take adequate measures.

CAUTION

This appliance is intended for use in environments which are relatively free of electromagnetic fields.

Using this appliance near sources of strong electromagnetic fields or where electrical noise may overlap with the input signals could cause the picture and sound to wobble or cause interference such as noise to appear.

To avoid the possibility of harm to this appliance, keep it away from sources of strong electromagnetic fields.

To prevent electric shock, ensure the grounding pin on the AC cord power plug is securely connected.

FOR UK ONLY

IMPORTANT: THE MOULDED PLUG

FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY.

This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 5 amp fuse is fitted in this plug. Shall the fuse need to be replaced, please ensure that the replacement fuse has a rating of 5 amps and that it is approved by ASTA or BSI to BS1362.

Check for the ASTA mark ASA or the BSI mark on the body of the fuse.

If the plug contains a removable fuse cover, you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover the plug must not be used until a replacement cover is obtained.

A replacement fuse cover can be purchased from your local JVC Dealer.

If the fitted moulded plug is unsuitable for the socket outlet in your home, then the fuse shall be removed and the plug cut off and disposed of safety. There is a danger of severe electrical shock if the cut off plug is inserted into any 13 amp socket.

If a new plug is to be fitted, please observe the wiring code as shown below.

If in any doubt, please consult a qualified electrician.

WARNING:

 

 

THIS APPARATUS MUST BE EARTHED.

 

IMPORTANT:

 

 

 

The wires in this mains lead are coloured in accordance with the following code:

 

 

 

 

 

 

 

 

Green-and-Yellow: Earth

 

 

 

 

 

Blue:

Neutral

 

 

 

 

 

Brown:

Live

As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is

marked with the letter E or by the Earth symbol or coloured GREEN or GREEN-AND-YELLOW.

The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter N or coloured BLACK.

The wire which is coloured BROWN must be connected to the terminal in the plug which is marked with the letter L or coloured RED.

How to replace the fuse. Open the fuse compartment with a screwdriver and replace the fuse.

3

Image 3
Contents Plasma Display Monitor GD-V502PCEINSTRUCTIONS Table of Contents Green-and-Yellow Earth Important Safety NoticeFor Your SAFETY, Please Read the Following Text Carefully This Apparatus Must be EarthedSafety Precautions SetupWhen using the Plasma Display Cleaning and maintenance If problems occur during useElectric shocks can result if this is not done Accessories Accessories SupplyRemote Control Batteries Connections SpeakersAC cord fixing SDA HD/SYNC SCL Signal Names for mini D-sub 15P ConnectorGND Ground Signal Name PC Input Terminals connectionCommunication parameters Installing the ferrite core Large sizeCommand Serial Terminals connectionBasic Controls Off Connecting the AC plug to the Wall Outlet Power On/Off and input signal selectionPower On/Off Power Indicator Remote Control SensorEnglishus Select the input signalSelecting the On-Screen Menu Language INPUT1 INPUT2 INPUT3On-Screen Menu Displays Press to Set up Press to access each adjust screen From the unitPress to Setup To setup Multidisplay screenJust Mode Picture ExplanationAspect Controls ZoomPos Adjusting Picture Pos./SizeAdjusting screen Helpful Hint N / Normalise NormalisationCinema Picture AdjustmentsNormal DynamicAGC Advanced settingsMute Sound AdjustmentSelect the magnification required for the enlarged display Digital ZoomDisplay the Operation Guide Select the area of the image to be enlargedPresent Time Present Time Setup / Set up TimerPresent Time Setup Press to exit from Present Time SetupDisplay the Set up Timer screen Press to select Set up TimerReversal / Scroll selection Mode selectionStart setting Screensaver For preventing after-imagesSetup of Screensaver Time Reduces screen after-imagePress to select Screensaver This function may be applicable to the non-picture area Side Panel AdjustmentReduces power consumption Customizing the Input labelsINPUT3/VIDEO3/COMPONENT3/RGB3/PC3/DVD3/CATV3/VCR3/STB3 How to Setup Multi Display Setup for Multi DisplayNTSC, PAL, Secam Press to select 2 ⋅ 2, 3 ⋅RGB Setup for Input SignalsComponent/RGB-in Select 3D Y/C Filter For Ntsc AV imagesPAL Secam Ntsc Colour system / Aspect AutoCinema reality If the picture image becomes unstableDisplays the H Horizontal/V Vertical frequencies Setting RGB sync signalSync Freq. kHz/V-Freq. HzPlasma Display panel Symptoms Check TroubleshootingApplicable input signals for PC Input Mini D-sub 15P ∗ Mark Input signal can be displayedGD-V502PCE SpecificationsGD-V502PCE Plasma Display Monitor