Parameters used for the data format
The following 2 types of parameters are used for command and response data:
(1)ON/OFF (2) Special Parameter Each parameter is as follows:
(1) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character | Hex | Meaning |
|
|
|
0 | 30 | OFF |
|
|
|
1 | 31 | ON |
|
|
|
(2) Special parameters Operation mode parameters
Character | Hex | Meaning | |
|
|
|
|
0000 | 30 30 30 30 | Standby state | |
|
|
|
|
0001 | 30 30 30 31 | Power ON state | |
|
|
|
|
0002 | 30 30 30 32 | Cooling state | |
|
|
|
|
0003 | 30 30 30 33 | Emergency cooling state | |
|
|
|
|
0004 | 30 30 30 34 | Emergency state | |
|
|
|
|
DHCP client parameters |
|
| |
|
|
|
|
Character | Hex | Meaning |
|
|
|
|
|
0 | 30 | DHCP |
|
|
|
|
|
1 | 31 | Static IP |
|
|
|
|
|
IP address parameters
Display the IP address using the dot (“.” (2HE)) delimiter.
Example: “192.168.0.10”
External control command table
Function | Command | Setting | Asking |
|
| Data Type | |||
|
|
|
|
|
|
|
| ||
Power On | ELSE | Power On |
| ELSE | ON/OFF |
| Special Parameter | ||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
Power | U0F | 3(OFF) | 3(ON) | - |
| - | 3 |
| - |
|
|
|
|
|
|
|
|
|
|
Hide | U00 | 3 | - | 3 |
| - | 3 |
| - |
|
|
|
|
|
|
|
|
|
|
Operation Mode | UA0 | - | - | 3 |
| 3 | - |
| Standby... |
|
|
|
|
|
|
|
|
|
|
DHCP Client | UD2 | 3 | 3 | 3 |
| 3 | - |
| DHCP... |
|
|
|
|
|
|
|
|
|
|
IP Address | UD3 | 3 | 3 | 3 |
| 3 | - |
| 192.168. ... |
|
|
|
|
|
|
|
|
|
|
Network Restart | UDC | 3 | 3 | 3 |
| 3 | - |
| [0] Fixed |
|
|
|
|
|
|
|
|
|
|
NOTE:
●After configuring the ADHCP ClientB and AIP AddressB, execute ANetwork RestartB.
35