5 Test Setup

The HPA072 has the following input/output connections: 12-V input J1 (VIN) and J2 (GND),

1.5-V output J9 (VOUT) and J10 (GND). A diagram showing the connection points is shown in Figure 5. A power supply capable of supplying 18 A should be connected to VIN and GND through a pair of 10 AWG wires. The 1.5-V load should be connected respectively to J9 and J10 through pairs of 0 AWG wires. Wire lengths should be minimized to reduce losses in the wires. A 5-inch fan with 200-cfm air flow is recommended to operate this board at full load.

12 V/ 20 A

Power

Supply

J1

J2

Oscilloscope

CH1

J8

TPS40090EVM−002

Board

J9

J10

Fluke 45

VOUT DC

Electronic

Load

UDG−04063

Figure 7. Connections for the Test

14TPS40090 Multi-Phase Buck Converter and TPS2834 Drivers Steps-Down from 12-V to 1.5-V at 100 A

Image 14
Contents User’s Guide EVM Important Notice Dynamic Warnings and Restrictions Introduction Features SchematicTransen Component Selection Frequency of OperationInductance Value Input Capacitor SelectionOutput Ripple Cancellation and Capacitor Selection PH, D + if N PH v 1, DI OUTD, DI OUT N PH, DVout Iripple + LMosfet Selection Current SensingOvercurrent Limit Protection OUTCompensation Components R11Test Setup Connections for the TestTest Results and Performance Data Efficiency and Power LossTotal Power Loss Output Current Overall Efficiency Output CurrentOutput Ripple and Noise Gain and Phase Oscillator FrequencyClosed-Loop Performance Transient Response Transient ResponseStart up with Pre-Biased Output J11 Short CircuitLayout Considerations EVM Assembly Drawing and PCB Layout Top Side Component AssemblyTop Side Copper Internal 2 Power Plane Bottom Layer Copper List of Materials QTYLoad Transient Circuit Important Notice Products Applications