Runco VX-22D manual Home Theater Calibration Specifications, Industry-Standard Specifications

Page 80

Specifications

Table 7-1. VX-22d Specifications (continued)

Brightness and Contrast:

Cinema Standards Measurement System (CSMS)

 

Specifications

 

-

Brightness: 58.7 foot-Lamberts (fL)

 

-

Contrast Ratio: 321:1

 

These measurements are taken from the projector in a controlled,

 

home theater environment. All measurements are made to

 

ANSI/NAPM IT7.228-1997 specifications using the Photo Research

 

PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter,

 

Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The

 

projector is calibrated to a color temperature of 6,500K and has a

 

minimum of 150 hours of usage.

 

The foot-Lambert (fL) is the unit of measurement used in commercial

 

movie theaters to express image brightness at the screen surface. The

 

Society of Motion Picture and Television Engineers (SMPTE) specifies

 

16 fL as the target image brightness for film-based projectors using an

 

open gate (without film in the projector). More importantly, today

 

SMPTE specifies 12 fL as the target image brightness in Digital

 

Cinema theaters. The foot-Lambert measurement is dependent on

 

screen size, screen gain and projector light output.

 

Home Theater Calibration Specifications

 

-

Light Output: 1391 ANSI Lumens

 

-

Contrast Ratio: 321:1

 

These specifications are obtained by calibrating the projector as

 

described above for CSMS measurements.

 

Industry-Standard Specifications

 

-

Light Output: 2850 ANSI Lumens

 

-

Contrast Ratio: 4000:1

 

These are typical projector brightness and contrast specifications

 

found in most companies’ sales literature. Runco includes these

 

measurements in its literature to allow for direct comparison with other

 

manufacturers’ projectors. These measurements are typically taken at

 

9,000K to 13,000K to get expected performance data when the

 

projector is used in professional, commercial and industrial displays.

 

 

Power Requirements:

100 to 240 VAC (auto-sensing), 50/60 Hz, 530 Watts

 

 

Operating Environment:

41°F to 95°F (5°C to 35°C), 0% to 90% humidity

 

(non-condensing)

 

 

Dimensions:

See Figure 7-1

 

 

Weight (without lens):

99.21 lbs. (45.00 kg)

 

 

Regulatory Approvals:

Complies with FCC, CE C-Tick

 

 

Limited Warranty:

Projector: Two (2) years parts and labor from the date of

 

delivery to the end user.

 

Lamp: 1000 hours or six (6) months, whichever comes first.

Specifications are subject to change without notice.

68

Runco VX-22d Owner’s Operating Manual

Image 80
Contents VX-22d Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Runco INTERNATIONAL, INC Safety Precautions Table of Contents Operation Maintenance and Troubleshooting Table of Contents List of Figures List of Figures Xii Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Functions VX-22d at a GlanceVX-22d Rear Panel VX-22d Rear PanelDVI-DL Dual-Link Power Input 100 to 240 VAC Connect the VX-22d to power hereUSB-B DHD Controller Front Panel DHD Controller Front PanelIssue LED Service only For future use DHD Controller Rear PanelDVI-DL DUAL-LINK Output 1080p RS-232/485 Control PortVolt 750 mA Trigger Outputs Hdmi I 1 / Hdmi II 2 DigitalVX-22d Remote Control VX-22d Remote ControlPicture Adjustment Buttons BRT Brightness On / OFFSource Selection Buttons VID S-VideoMemory Preset Buttons Aspect Ratio Selection Buttons169 Lbox LetterboxInstallation Remote ControlIf installing an VX-22d/CineWide with AutoScope Quick SetupStep Procedure For Details, Refer to Ambient Light Installation ConsiderationsInstallation Type Throw Range Throw Ratio Inches, with Lens Option 96x54-inchLens Lens Only Anamorphic Minimum MaximumCeiling Installation Floor InstallationVertical and Horizontal PositionHorizontal Lens Shift Example only Folded Optics Folded OpticsInstalling the Primary Projection Lens Other ConsiderationsInstallation Installing the Optional CineWide/AutoScope Lens Motor Remove Projector FrontFeet RemoveInstall AutoScope Lens MotorInstall Ceiling Mount Extension BracketsMounting the VX-22d Connecting the VX-22d to the DHD Controller Connections to the VX-22d and DHD ControllerHdmi Source HD-DVD/BD/DVD Player or HD Tuner with Connecting Source Components to the DHD ControllerHdmi Connections See Figure Digital DTV RGB or Component Video Connections HD1, HD2 10. Digital DTV RGB or Component Video Connections HD3 Analog Computer RGB Connections See Figure 11. Analog RGB ConnectionsVideo/Composite Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcRS-232 Controller Connection14 -volt Trigger Output Connections DHD Controller Rear Panel Connecting an External IRReceiver to the DHD Connecting to AC Power Turning on the PowerAdjusting the Picture Orientation Adjustments Primary LensFocus ZoomIt is extremely important that the primary lens is properly Installing and Adjusting the CineWide Anamorphic LensAttach Lens Mounting Assembly to Lens Motor Carriage Plate 17. Attaching the Anamorphic Lens to the Lens Adapter Ring Adjusting the Horizontal X Lens Position Configure Lens Motor Trigger Adjust the Anamorphic LensInstallation Anamorphic Lens Top View Adjusting the Geometry Wrong PositionUsing the On-Screen Menus OperationISF Presets ServiceInput Source Aspect RatioAspect Ratio Main MenuInput Source Remote Aspect Ratio Control Description Key 169 Select 169 to view 169 DVDsHdtv programs in their Native aspect ratioPicture PictureRemote Aspect Ratio Control Description Key Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Input PositionISF Presets ISF PresetsInformation InformationISF Day CalibrationCalibration ISF Night Gain/Offset Refer to ISF Night Display Color, above HD Format ServiceService ISF Day/Night presets Maintenance and Troubleshooting Lamp ReplacementFilter Replacement Side Filter Access PanelTroubleshooting Tips Symptom Possible Causes SolutionMaintenance and Troubleshooting If you are using a PC to communicate with the DHD Controller Serial CommunicationsAspect Ratio Commands Command Description ResponseInput Selection Commands Command Description Response Image Preset Commands Menu Navigation CommandsPicture Adjust Commands Enter or Select buttonSerial Communications Specifications VX-22d SpecificationsHome Theater Calibration Specifications Industry-Standard SpecificationsPower Requirements DimensionsDHD Controller Specifications VX-22d Dimensions 1shows the VX-22d dimensions all dimensions are in inchesPage Runco CL-810 Owner’s Operating Manual