Sharp PG-D3550W Adjusting the Image, Adjusting the Color Temperature, Adjusting the Colors

Page 47

2 Adjusting the Image

Adjustment

O button

Q button

items

 

 

Contrast

For less

For more

 

contrast.

contrast.

Bright

For less

For more

 

brightness.

brightness.

Color*1

For less color

For more color

 

intensity.

intensity.

Tint*1

For making skin

For making skin

 

tones purplish.

tones greenish.

Sharp*1

For less

For more

 

sharpness.

sharpness.

Red*2

For weaker red.

For stronger

 

 

red.

Blue*2

For weaker

For stronger

 

blue.

blue.

BrilliantColor™*2 *3

For making the

For making the

 

effect weaker.

effect stronger.

*1 Not displayed in the RGB input mode.

*2 Not adjustable/selectable when selecting “sRGB”.

*3 BrilliantColor™ uses Texas Instruments' BrilliantColor™ technology. As the BrilliantColor™ level is increased, the image becomes brighter while the color reproduction is kept at a high level.

Note

“Red”, “Blue”, “BrilliantColorTM” and “CLR Temp” cannot be set when “sRGB” is selected.

To reset all adjustment items, select “Reset” and press ENTER.

Adjusting the Color

Temperature

Selectable

Description

items

 

 

 

For lower color temperature for

–1

warmer, reddish incandescent-like

0

images.

 

 

 

 

 

 

 

1For higher color temperature for cooler, bluish, fl uorescent-like images.

Note

Values on “CLR Temp” are only for general standard purposes.

Menu operation n Page 40

4 Adjusting the Colors

This function adjusts each of the six main colors that comprise the color wheel, altering their “Hue”, “Saturation”, or “Value”.

Selectable items

Description

C.M.S.-Hue

Sets the hue of the main colors.

 

 

C.M.S.-Saturation

Sets the saturation of the main

 

colors

C.M.S.-Value

Sets the brightness of the main

 

colors.

Reset

The adjustments of “Hue”,

 

“Saturation” and “Value” of all

 

colors are reset to the default

 

setting.

 

 

Return

Returns to the “Picture” menu

 

screen.

Adjusting “Hue”, “Saturation”, or “Value”.

1Select “On” for “C.M.S. Setting” in the “Picture” menu and then press ENTER.

2Select “C.M.S.” in the “Picture” menu and then press ENTER.

3Press P or R to select either “Hue”, “Saturation”, or “Value” and then press ENTER.

4Select the color to be adjusted with P or R and adjust it with O or Q.

Example of adjusting the “Hue”

Main colors

O button

Q button

 

 

 

R (Red)

Closer to magenta

Closer to yellow

 

 

 

Y (Yellow)

Closer to red

Closer to green

G (Green)

Closer to yellow

Closer to cyan

 

 

 

C (Cyan)

Closer to green

Closer to blue

B (Blue)

Closer to cyan

Closer to magenta

 

 

 

M (Magenta)

Closer to blue

Closer to red

When “Saturation” is selected, the selected

color becomes

O: lighter. Q: thicker.

When “Value” is selected, the selected color

becomes

O: darker. Q: brighter.

To reset the adjustment values of each color to the default settings, select “Reset” and press

ENTER.

Features

Useful

43

Image 47 Contents
PG-D3550W/PG-D3050W PG-D3550W PG-D3050W PG-D2870WModel No Serial No Iii Page Void the users authority to operate this equipment See bottom of projectorInformation Product Disposal For Future Reference Using the Menu ScreenContents Reference Adjusting the Projector Function PRJ ADJ1/2 MenuPower-Cord Protection CleaningPower Sources AccessoriesOverloading Damage Requiring ServiceReplacement Parts Safety CheckDo not block the exhaust and intake vents Avoid locations with extremes of temperatureRest your eyes occasionally Closed Caption uses Bitstream Vera fonts Using the projector in other countriesTemperature monitor function Other connected equipmentFor Macintosh When you want to view the Setup ManualFor Windows Optional accessories AccessoriesPG-D2870W Part Names and FunctionsRear View Terminals Using the Kensington LockPicture Mode button For automatically adjusting images whenVOL +/- Volume buttons Break Timer buttonUsable Range Remote control signal transmittersInserting the Batteries Easy Start Setup and ProjectionWhen connecting equipment other than a computer, see pages On the projector On the remote controlTurn the computer on Turn the power off Standard Setup Front Projection Setting Up the ProjectorVideo Setup Setting Up the ProjectorScreen Lens center Signal Input Normal ModeScreen Size and Projection Distance Ceiling-Mount Setup Projection PRJ ModeYou may need other cables or connectors not listed below Connecting the Projector to Other EquipmentConnecting the Projector to Other Equipment RGB Controlling the Projector by a Computer AC socket To AC outlet Power cord Supplied Connecting the Power CordWhen connecting to the LAN terminal using a LAN cable Standby button On button Power indicator Lamp indicatorTurning the Projector On/Off Turning the Projector OnImage Projection About the Setup GuideAdjusting the Projected Image Adjusting the Focus Press Enter to exit the Setup Guide screenRotate the zoom ring to enlarge or shrink the picture size Adjusting the HeightAdjusting the Picture Size except PG-D2870W Use the rear adjustment foot to make the projector levelShrinks lower side Correcting Trapezoidal DistortionPress Keystone On-screen display Switching the Input ModeAdjusting the Volume Input buttons AV Mute button VOL +/- Volume buttons ButtonsPress Resize Resize ModeAbout Copyrights Switching the Eco+Quiet Mode Operating with the Remote ControlDisplaying and Setting the Break Timer Using the Spot FunctionFreezing a Moving Image Selecting the Picture ModeWhen right-clicking Using the Remote Control as the Wireless Computer MouseWhen moving the cursor When left-clickingPicture menu Menu ItemsItem when selecting S-VIDEO or Video Network menu Example Using the Menu Screen Menu Selections Quick Start Menu Press MenuFollowing items can be configured on the Quick Start Menu Example Adjusting BrightQuick Start Menu Menu Selections Complete MenuPress Enter To adjust the projected image while watching itPress P or R and select Bright to adjust Press O or Q to adjust the item selectedMenu operation n Picture Adjustment Picture MenuSelecting the Picture Mode Adjusting Hue, Saturation, or Value Adjusting the ImageAdjusting the Color Temperature Adjusting the ColorsReducing Image Noise DNR Selecting the Film ModeEco+Quiet Signal Type Setting Signal Adjustment SIG-ADJ MenuResolution Setting When reproducing Ntsc signals in PAL video equipment Setting the Video SystemSetting the Video Setup Checking the Input SignalKeystone Correction Adjusting the Projected Image SCR-ADJ MenuSetting the Resize Mode Adjusting the Image PositionFor Americas only Setting the OverscanSetting the On-screen Display Closed CaptionSelecting the Wall Color Selecting the Setup GuideSelecting the Background Image Reversing/Inverting Projected ImagesAuto Restart Function Auto Sync Auto Sync AdjustmentAuto Power Off Function Speaker SettingEnter the same keycode in Re- confirm Fan Mode SettingSystem Lock Function COMPUTER2 Select Adjusting the Projector Function PRJ-ADJ1/2 MenuKeylock Function Selecting the Quick Start MenuChecking the Lamp Life Status Setting the Function Button OperationStandby Mode Standby Audio OutOn the projector, press Setting a PasswordSelect Password, then press Enter or Q Enter the same password in Reconfirm, then press EnterEnter IP Address using P, R, Q and O, then press Enter Dhcp Client SettingTCP/IP Setting Returning to Default Settings NetworkYou can confirm the following items Setting Up the Projector Network Environment Network MenuConfirming the Projector Information Cleaning the exhaust and intake vents MaintenanceCleaning the projector Cleaning the lensAbout the lamp indicator Maintenance IndicatorsAbout the temperature warning indicator Red on Abnormally high Are high Lower than 95F +35ºC Replacing the Lamp Regarding the LampLamp STANDBY/ON button AC socket Removing and Installing the Lamp UnitRemove the lamp unit cover Lamp unitResetting the Lamp Timer Place the projector into the storage case How to Use the Storage CaseStoring the Projector Open the cover of the storage caseComputer Compatibility Chart21-25 Troubleshooting57, 58 Sharp Electronics Corporation Specifications Dimensions Index