Sharp PG-D3510X appendix Rest your eyes occasionally, Avoid locations with extremes of temperature

Page 12

Observe the following safeguards when setting up your projector.

Caution concerning the lamp unit

Potential hazard of glass particles if lamp

ruptures. In case of lamp rupture, contact your nearest Sharp Authorized Projector Dealer or Service Center

for replacement.

See “Regarding the Lamp” on page 60.

Caution concerning the setup of the projector

For minimal servicing and to maintain high image quality, SHARP recommends that this projector be installed in an area free from humidity, dust and cigarette smoke. When the projector is subjected to these environments, the vents and lens must be cleaned more often. As long as the projector is regularly cleaned, use in these environments will not reduce the overall operation life of the unit. Internal cleaning should only be performed by a Sharp Authorized Projector Dealer or Service Center.

Rest your eyes occasionally.

Continuously watching the screen for long hours will cause eye strain. Take regular breaks to rest your eyes.

When using the projector in high- altitude areas such as mountains (at altitudes of approximately 1,500 meters (4,900 feet) or more)

When you use the projector in high-altitude areas with thin air, set “Fan Mode” to “High”. Neglecting this can affect the longevity of the optical system.

Use the projector at altitudes of 2,300 meters (7,500 feet) or less.

Warning about placing the projector in a high position

When placing the projector in a high position, make certain it is carefully secure to avoid personal injury caused by the projector falling down.

Do not subject the projector to hard impact and/or vibration.

Protect the lens so as not to hit or damage the surface of the lens.

Avoid locations with extremes of temperature.

The operating temperature of the projector is from 41°F to 95°F (+5°C to +35°C).

The storage temperature of the projector is from –4°F to 140°F (–20°C to +60°C).

Do not set up the projector in places exposed to direct sunlight or bright light.

Position the screen so that it is not in direct sunlight or room light. Light falling directly on the screen washes out the colors, making viewing difficult. Close the curtains and dim the lights when setting up the screen in a sunny or bright room.

Caution regarding placing of the projector

Place the projector on a level site within the adjustment range (9 degrees) of the adjustment foot.

After the projector is purchased, a faint smell from the vent may appear when the power is first turned on. This is normal and is not a malfunction. It will disappear after the projector is used for a while.

Do not block the exhaust and intake vents.

Allow at least 11 13/16 inches (30 cm) of space between the exhaust vent and the nearest wall or obstruction.

Ensure that the intake vent and the exhaust vent are not obstructed.

If the cooling fan becomes obstructed, a protection circuit will automatically put the projector into Standby mode to prevent overheat damage. This does not indicate a malfunction. (See pages 58 and 59.) Remove the projector power cord from the wall outlet and wait at least 10 minutes. Place the projector where the intake and exhaust vents are not blocked, plug the power cord back in and turn on the projector. This will return the projector to the normal operating condition.

8

Image 12
Contents PG-D3510X PG-D3010X PG-D2710X Model No Serial No Iii Page See bottom of projector Void the users authority to operate this equipmentInformation Product Disposal Maintenance Troubleshooting Index Using the Menu ScreenFor Future Reference Contents Adjusting the Projector Function PRJ ADJ1/2 Menu ReferenceCleaning Power SourcesAccessories Power-Cord ProtectionDamage Requiring Service Replacement PartsSafety Check OverloadingAvoid locations with extremes of temperature Rest your eyes occasionallyDo not block the exhaust and intake vents Using the projector in other countries Temperature monitor functionOther connected equipment Closed Caption uses Bitstream Vera fontsWhen you want to view the Setup Manual For WindowsFor Macintosh Accessories Optional accessoriesPart Names and Functions Front ViewUsing the Kensington Lock Rear View TerminalsFor automatically adjusting images when VOL +/- Volume buttonsBreak Timer button Picture Mode buttonRemote control signal transmitters Inserting the BatteriesUsable Range Setup and Projection When connecting equipment other than a computer, see pagesOn the projector On the remote control Easy StartTurn the computer on Turn the power off Setting Up the Projector Setting Up the ProjectorStandard Setup Front Projection Signal Input Normal Mode Signal Input 169 ModeScreen Size and Projection Distance Screen Lens centerProjection PRJ Mode Ceiling-Mount SetupConnecting the Projector to Other Equipment Terminals on the ProjectorConnecting the Projector to Other Equipment RGB Controlling the Projector by a Computer Connecting the Power Cord When connecting to the LAN terminal using a LAN cableAC socket To AC outlet Power cord supplied Power indicator Lamp indicator Turning the Projector On/OffTurning the Projector On Standby button On buttonAbout the Setup Guide Adjusting the Projected Image Adjusting the FocusPress Enter to exit the Setup Guide screen Image ProjectionAdjusting the Height Adjusting the Picture SizeUse the rear adjustment foot to make the projector level Make small adjustments Height Adjust leverPress Keystone to enter the Keystone Correction mode Press P/Q or O/R to adjust Keystone CorrectionCorrecting Trapezoidal Distortion Press KeystoneSwitching the Input Mode Adjusting the VolumeInput buttons AV Mute button VOL +/- Volume buttons Buttons On-screen displayResize Mode Press ResizeAbout Copyrights Operating with the Remote Control Displaying and Setting the Break TimerUsing the Spot Function Switching the Eco+Quiet ModeSelecting the Picture Mode Freezing a Moving ImageUsing the Remote Control as the Wireless Computer Mouse When moving the cursorWhen left-clicking When right-clickingMenu Items Picture menuMain menu Network menu Using the Menu Screen Menu Selections Quick Start MenuPress Menu ExampleExample Adjusting Bright Quick Start MenuMenu Selections Complete Menu Following items can be configured on the Quick Start MenuTo adjust the projected image while watching it Press P or R and select Bright to adjustPress O or Q to adjust the item selected Press EnterPicture Adjustment Picture Menu Selecting the Picture ModeMenu operation n Adjusting the Image Adjusting the Color TemperatureAdjusting the Colors Adjusting Hue, Saturation, or ValueSelecting the Film Mode Eco+QuietReducing Image Noise DNR Signal Adjustment SIG-ADJ Menu Signal Type SettingResolution Setting Setting the Video Setup When reproducing Ntsc signals in PAL video equipmentAdjusting the Projected Image SCR-ADJ Menu Setting the Resize ModeAdjusting the Image Position Keystone CorrectionSetting the Overscan Setting the On-screen DisplayClosed Caption For Americas onlySelecting the Setup Guide Selecting the Background ImageReversing/Inverting Projected Images Selecting the Wall ColorAuto Sync Auto Sync Adjustment Auto Power Off FunctionSpeaker Setting Auto Restart FunctionFan Mode Setting Preset keycode in Old CodeSystem Lock Function Press the 4 buttons on the remoteAdjusting the Projector Function PRJ-ADJ1/2 Menu Keylock FunctionSelecting the Quick Start Menu COMPUTER2 SelectSetting the Function Button Operation Standby ModeReturning to the Default Settings Checking the Lamp Life StatusSetting a Password Select Password, then press Enter or QEnter the same password in Reconfirm, then press Enter On the projector, pressDhcp Client Setting TCP/IP SettingReturning to Default Settings Network Enter IP Address using P, R, Q O, then press EnterSetting Up the Projector Network Environment Network Menu Confirming the Projector InformationYou can confirm the following items Maintenance Cleaning the projectorCleaning the lens Cleaning the exhaust and intake ventsMaintenance Indicators About the temperature warning indicatorAbout the lamp indicator Red on Abnormally high Are high Lower than 95F +35ºC Regarding the Lamp LampReplacing the Lamp Removing and Installing the Lamp Unit Remove the lamp unit coverLamp unit STANDBY/ON button AC socketResetting the Lamp Timer How to Use the Storage Case Storing the ProjectorOpen the cover of the storage case Place the projector into the storage caseComputer Compatibility Chart ComputerTroubleshooting 21-2557, 58 Sharp Electronics Corporation Specifications Dimensions Index
Related manuals
Manual 26 pages 18.55 Kb