Motorola T2-2500, 45101 manual Configuration Files using the webUI, File dir

Page 14

System Administration

a.Source can be a local file, a remote FTP or TFTP file, or a pre-defined keyword. Keywords allow you to capture the startup and running configuration to a file. Supported keywords are “startup” and “running”.

b.Destination can be a local file or a remote FTP or TFTP file. Note that the combination of the Source keywords and the remote Destination allows you to copy the running config directly to a remote server. For example; file copy running to tftp://192.168.1.1/my-t2-config.txt

c.At least one (source or destination) must be the local file system. If the source and destination are remote servers, the command will fail.

file delete <string(file)>

d.Delete a file from the file system

file dir

e.List the files in the system and display the remaining storage file exec <string(file)>

f.Executes a file as a set of configuration commands. Note that “file” is a local file in the file system. The file must have previously been copied to the filesystem from the external server using the file copy command.

Configuration Files using the webUI

From the webUI, the administrator can save and load configuration files. Note that these configuration files are non- editable binary format for configuration security. If editable configuration is desired, use the CLI script files. Configuration files from the webUI can be used to create secure template configurations.

Note: The Configuration File contains every configuration possible including the “Admin” account password. When combined with RADIUS network authentication, the non-editable Configuration Files provide a secure method to pre- configure systems in a staging area and apply the secure “admin” password without revealing the password. Contact a Tut Systems support person for assistance with a setting up secure, staged configurations.

To save or load a Configuration file from the webUI, access the System – Configuration screen from the webUI.

Follow these steps to create a template configuration file:

1.Configure a complete system configuration

2.Set the system name to “template configuration” or similar name

3.Save the configuration file using the webUI System-Configuration screen

Follow these steps to apply the template to a new system:

1.Boot a new system

2.Using the serial console login, set the IP address (or use the default IP address)

3.Reboot the system to apply the IP address

4.Login via the webUI

5.Load the template configuration file using the System-Configuration screen

6.Change the system name to the correct name

7.Change the IP address to the correct IP address

8.Power off or reboot the system. The next time the system is booted, it will have the complete configuration with the correct IP address and system name.

Motorola, Inc.

549453-001-00-a

Page 14 of 51

 

 

 

Image 14
Contents Aka mT2a EthernetXD Page Regulatory Statements Model Number45125 MT2a Switch M2 WallPlateWaste Electrical and Electronic Equipment Weee Commands and Syntax Quality of Service QoS Administrative Commands Commands and SyntaxCommand Hierarchy Show CommandsStyle Conventions Command DescriptionCommand Completion Interface RangeModel Number HardwareModel Numbers and Description Mounting Options Switch Front Panel ConnectionsSwitch Rear Panel Connections M2a 2 port WallPlate M4a 4 port Service UnitWallPlate M4a 4 port WallPlateCLI Configuration Script files System AdministrationManagement Access Access MethodsConfiguration Files using the webUI File dirLine Quality Http MenusUpgrading the System Image System Menu Interface Menu Advanced Menu Monitor MenuSummary Startup Running View System Configuration and StatusCommit mode System config mode automanualmode Reset to Default ConfigurationOther Configuration Help Access Control Lists ACLs Ip access-list config 1 deny httpRadius network authenticated login Mounting options for existing telco box WallPlate InstallationInstallation Guidelines Other mounting optionsInstall RJ11 line cable Installation 1 Install over 70mm x 114mm wall plateInstall bracket over existing wall plate Attach cover to the bracketVariance from Country to Country Remove and discard cover over existing wall plateConnect RJ11 cable Installation 3 External mounting tabsRemove the cover to service the WallPlate Assemble the m2 WallPlateInstall cross connects Installation StepsInstall mT2 switch in phone room MDF or IDF Review the cross-connectsConfigure mT2 EthernetXD Switch Components provided with the m2a WallPlate In-Room InstallationTools Required Components required to purchaseStep Determine which port is being installed Enable line powerFinish the installation Enable line powerVlan terminology Vlan Specification802.1Q VLANs Tagged UntaggedVlan commands in mT2 Tag-based Vlan Mode Port-based Vlan ModeWeb UI configuration Vlan General webUISet Vlan Egress Rules Tag-based Vlan webUICreate/Delete VLANs Set Vlan Ingress RulesPort-based Vlan webUI Quality of Service QoS QoS commands and conceptsNetwork qos interface queue interface-id mode mode Queue Dynamic packet classification802.1P bit Packet Classification CommandsQoS Example Packet transmissionVlan Tutorials Tutorial 1 Simple Hotel configurationThird party network configuration Privacy and QoS in this networkTutorial 2 Mixed Mode Vlan configuration with QoS This networkEnable and create VLANs, Enable QoS Port VLAN-Ids used in this configurationTutorial 3 Per port 802.1Q VLANs Enable VLANs, configure PVIDs Convert this tutorial to a real-world configurationEth1 Eth2 Port Motorola, Inc 549453-001-00-a SwitchEth1 Eth2 Port Enable VLANs, configure Vlan modes Optional configuration on the cascaded switchLine Status Line Current Watts ReferenceRS-232 console port RJ21 Line ConnectorsAppendix a Pin-out Assignments Gigabit Ethernet ports Fast Ethernet WallPlate portsM2 WallPlate Appendix B Hardware SpecificationsMT2 Switch Page FCC Part 15A Important Safety Instructions mT2a SwitchAppendix C Compliance M2a WallPlate

45101, T2-2500 specifications

The Motorola T2-2500,45101 is a versatile and robust two-way radio that exemplifies the advanced communication technologies of its time. Designed for both professional and industrial use, this device stands out due to its durability and functionality, making it a popular choice among a range of users, from security personnel to event coordinators.

One of the main features of the T2-2500 is its powerful audio output, ensuring clear and audible communication even in noisy environments. This is particularly vital for users who rely on efficient communication to ensure safety and coordination in demanding situations. The radio incorporates advanced noise-cancellation technology which minimizes background interference, enhancing speech clarity.

The device operates on multiple channels, allowing users to select from various frequencies. This feature provides flexibility in communication, particularly in crowded areas where multiple teams might be communicating simultaneously. The T2-2500's channel scanning capability also enables users to monitor active channels quickly, promoting immediate responsiveness.

Battery life is a significant characteristic of the T2-2500, which boasts a long-lasting rechargeable battery. Users can rely on the radio throughout long shifts without the need for frequent recharging. Furthermore, the power-saving mode helps extend battery life even further, ensuring that communication remains uninterrupted.

The construction of the T2-2500 is designed to withstand the rigors of everyday use. Its rugged exterior is resistant to shocks, dust, and moisture, making it suitable for outdoor and challenging work environments. The device is also compliant with IP standards, ensuring it meets safety and performance requirements in adverse conditions.

Another noteworthy technology integrated into the T2-2500 is the ability to connect to compatible accessories. This includes earpieces for discreet communication and external microphones for hands-free operation. The adaptability of the device enhances its usability across different fields.

In summary, the Motorola T2-2500,45101 is not just a two-way radio; it represents a blend of technological advancement, user-friendly features, and rugged durability. Its powerful audio capabilities, long battery life, adaptability, and resilience make it an essential tool for anyone needing reliable communication in various professional settings. Whether for security, event management, or industrial applications, the T2-2500 stands out as a dependable communication solution.