Lithium Battery Warning

There is a danger of explosion if the Lithium battery in your chassis is incorrectly replaced. Replace the battery only with the same or equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. The manufacturer’s instructions are as follows: Return the module with the Lithium battery to Alcatel. The Lithium battery will be replaced at Alcatel’s factory.

Français: Il y a un danger d'explosion si la batterie de lithium dans votre châssis est inexactement substi- tuée. Substituez la batterie seulement avec la même chose ou le type équivalent de batterie recommandé par le constructeur. Rejetez les batteries utilisées selon les instructions du constructeur. Les instructions du constructeur sont comme suit : Renvoyez le module avec la batterie de lithium à Alcatel. La batterie de lithium sera substituée à l'usine d'Alcatel.

Deutsch: Es gibt eine Gefahr der Explosion, wenn die Lithiumbatterie in Ihrem Chassis falsch ersetzt wird. Ersetzen Sie die Batterie nur mit gleichen oder dem gleichwertigen Typen der Batterie empfohlen durch den Hersteller. Entledigen Sie sich benutzte Batterien entsprechend den Anweisungen des Herstell- ers. Die Anweisungen des Herstellers sind, wie folgt: Bringen Sie das Modul mit der Lithiumbatterie zu Alcatel zurück. Die Lithiumbatterie wird an der Fabrik Alcatels ersetzt.

Español: Hay un peligro de la explosión si la batería del litio en su chasis se substituye incorrectamente. Substituya la batería solamente por el mismo o el tipo equivalente de batería recomendado por el fabri- cante. Disponga de las baterías usadas según las instrucciones del fabricante. Las instrucciones del fabri- cante son como sigue: Vuelva el módulo con la batería del litio a Alcatel. La batería del litio será substituida en la fábrica de Alcatel.

Dansk: ADVARSEL! Lithiumbatteri--Eksplosionsfare ved fejlagtig handtering. Udskiftning ma kun ske batteri af samme fabrikat og type. Lever det brugte batteri tilbage tilleverandoren.

Operating Voltage Warning

To reduce the risk of electrical shock, keep your hands and fingers out of power supply bays and do not touch the backplane while the switch is operating.

Français: Pour réduire le risque de choc électrique, gardez vos mains et doigts hors des compartiments d'alimentation d'énergie et ne touchez pas la surface arrière tandis que le commutateur fonctionne.

Deutsch: Um die Gefahr des elektrischen Schlages zu verringern, halten Sie Ihre Hände und Finger aus Spg.Versorgungsteilbuchten heraus und berühren Sie nicht die Rückwandplatine während der Schalter steuert.

Español: Para reducir el riesgo del choque eléctrico, guarde sus manos y dedos fuera de bahías de la fuente de alimentación y no toque la placa madre mientras que el interruptor está funcionando.

OmniSwitch 6600 Series Hardware Users Guide April 2004

page A-7

Image 109
Contents OmniSwitch 6624/6648 Hardware Users Guide OmniSwitch 6600 Series Hardware Users Guide April Contents Contents Blank Cover Panels Index-1 Unsupported Platforms Supported PlatformsWhat is in this Manual? When Should I Read this Manual?What is Not in this Manual? Who Should Read this Manual?Stage 2 Gaining Familiarity with Basic Switch Functions Stage 1 Using the Switch for the First TimeHow is the Information Organized? Documentation RoadmapAnytime Stage 3 Integrating the Switch Into a NetworkRelated Documentation OmniSwitch 6600 Series Getting Started GuideTechnical Support OmniSwitch 6600 Series Stacked Configurations Stand-Alone and Stacked ConfigurationsStand-Alone Smart Continuous Switching Availability FeaturesHot Swapping Software RollbackHardware Monitoring Automatic MonitoringPort and Fabric Capacities OmniSwitch 6600 Series Fabric CapacitiesUser-Driven Monitoring OS6624/6600-U24 ThroughputSingle Office Building with 1000 Users Application ExamplesOmniPCX Medium Campus with 1500 UsersApplication Examples OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6624 Front Panel OmniSwitchConsole Port 10/100 Ethernet Ports10/100 Ethernet Port Specifications OS6624 SpecificationsOmniSwitch 6600-U24 Console Port Gigabit Ethernet Uplink Module Slot OmniSwitch 6600-U24 Front PanelOS6600-U24 Specifications SFP Mbps Ethernet SFP Port SpecificationsTM OmniSwitch OmniSwitch 6648 Front PanelOS6648 Specifications Front Panel LED Descriptions OS6648 Shown Status LEDsRedundant Power Supply Bay OmniSwitch 6600 Series Rear PanelPower Connector Socket Inline Power Connector Rear PanelOmniSwitch 6600 Series Chassis Top View Mounting the SwitchAirflow Considerations Installing the Switch on a Tabletop or Bench Installation OptionsAttaching a Rack-Mount Flange Attaching the Switch to the RackRack Mounting Stacked Configurations Specifications Power CordsPower Cord Types Grounding the ChassisPower Supply Redundancy Back Up Power SupplyBack Up Power Supply Front Panel Back Up Power Supply SpecificationsBack Up Factory-Installed Primary Power Supply OmniSwitch 6600 Series Redundant AC Circuit ExampleAC Circuit Back Up Factory-Installed Primary Power Supply Redundant AC Circuit RecommendationOrienting the Back Up Power Supply Installing a Back Up Power SupplyHot Swapping Tightening the Captive Screws Inserting the Back Up Power SupplyRemoving the Back Up Power Supply Removing a Back Up Power SupplyLoosening the Captive Screws Blank Cover Panel Requirement Viewing Primary and Back Up Power Supply StatusSlot Number is Specified Viewing Power Supply Status for Stacked ConfigurationsNo Slot Number is Specified OS6600-GNI-U2 Gigabit Ethernet Uplink ModulesOS6600-GNI-U2 Gigabit Ethernet Uplink Front Panel MiniGBIC SlotsOS6600-GNI-U2 Uplink Module Specifications OS6600-GNI-C2 OS6600-GNI-C2 Uplink Module SpecificationsOS6600-GNI-C2 Gigabit Ethernet Uplink Front Panel Copper Gigabit Ethernet PortsHssdc Stacking Connectors Stacking Module SpecificationsStacking Module Stacking Module Front PanelInserting the Uplink or Stacking Module Installing Uplink and Stacking ModulesInstalling Uplink and Stacking Modules Removing Uplink and Stacking Modules Removing the Module Mini Gigabit Interface Converter MiniGBIC Mini Gigabit Interface Converters MiniGBICsMiniGBIC-SX Technical Specifications MiniGBIC SpecificationsMiniGBIC-LX Technical Specifications MiniGBIC-LH-70 Technical SpecificationsInserting the MiniGBIC OS6648 Shown Installing MiniGBICsRemoving MiniGBICs Installed MiniGBIC OS6648 ShownSFP Module Mbps SFPs OS6600-U24SFP-100-LC-MM Technical Specifications Mbps SFP SpecificationsSFP-100-LC-SM15 Technical Specifications SFP-100-LC-SM40 Technical SpecificationsMtrj SFP-100-MTRJ-MM Technical SpecificationsInserting the SFP Installing SFPs OS6600-U24Removing SFPs OS6600-U24 Viewing Chassis Temperature Status Temperature ManagementViewing Temperature Status for Stacked Configurations Temperature Errors Viewing Fan Status Viewing Fan Status for Stacked ConfigurationsNo Slot Number is Specified Right Side Air Intake Vent Chassis AirflowLeft Side Fan Exhaust Vents Air Exhaust. The airflowEffects of Missing Blank Panels on Chassis Airflow Blank Cover PanelsPinouts RS232 Console Port Female DB9 Connector Pinout10/100 Ethernet Port RJ-45 Pinout Copper Gigabit Ethernet Port RJ-45 PinoutTXD RJ-45 Console Port Connector PinoutModifying the Serial Connection Settings Serial Connection Default SettingsConsole Port Serial Connection to the Console PortAdditional table output not shown Hardware Information Viewing Basic Chassis InformationSlot and Component Information Detailed Slot and Component Information Power onGbic IBM Basic Primary Slot and Component Information Basic Chassis Information OmniSwitch 6600 Series MAC Range Specifications Managing MAC Addresses on the SwitchMAC Range Guidelines Base Chassis MAC Address in Stacked Configurations Determining Current MAC Address Allocation on the SwitchBase Chassis MAC Address as Unique Identifier Viewing the Base Chassis MAC AddressThis Chapter Managing OmniSwitch 6600 Series StacksParameter Description Configuration Steps Default Value Specifications and Default ValuesStack Overview Stack Composed of Four OmniSwitch 6648 SwitchesSlot Numbers within a Stack Stacking Resiliency and RedundancyCMM Role Redundancy CMM Roles in a StackCMM Commands Switch PrimaryChassis Management and Monitoring Commands File Management CommandsMemory Monitoring Commands Switch Logging and Monitoring CommandsAssigning Slot Numbers Setting Up a Stacked ConfigurationSEL Button Location Continue to Connecting Cables to Stacking Ports onSlot Numbering Example Stack of Four Switches with Unique Slot NumbersValid Slot Assignments Attaching the Stacking Cable to a Stacking Port Connecting Cables to Stacking PortsRecommended Redundant Connection Between Switches Connecting the Switches in the StackRedundant Stack Connection Connection Failure Between Switches 1Stacking Cable Redundancy Example No Connection FailureVerifying Slot Number Assignments Booting the StackVerifying Primary and Secondary Status for the Stack Idle Status Reloading a Switch with a Primary or Secondary CMM Role Managing Switches in a StackReloading the Switch with the Primary CMM Role Reloading the Switch with the Secondary CMM RoleRestoring Switch Redundancy Synchronizing Switches in a StackModule Behavior During Takeover Changing the Secondary CMM Role to PrimaryResetting All Switches in a Stack Monitoring Stacks Managing and Monitoring OmniSwitch 6600 Series StacksMonitoring Stack Topology Secondary Active Monitoring Stacks Declaration of Conformity CE Mark Regulatory Compliance and Safety InformationSafety and Environmental Standards Safety StandardsStandards Compliance EMC StandardsCanada Class a Statement FCC Class A, PartCISPR22 Class a warning Class a Warning for Taiwan and Other Chinese Markets VcciChassis Lifting Warning Translated Safety WarningsBlank Panels Warning Electrical Storm WarningInvisible Laser Radiation Warning Installation WarningOperating Voltage Warning Lithium Battery WarningProper Earthing Requirement Warning Power Disconnection WarningRestricted Access Location Warning Read Important Safety Information WarningWrist Strap Warning Commit system command Commit file commandCopy flash-synchro command NumericsShow chassis command Show cmm command Show fan command Reload all command Reload commandTakeover command Temp-threshold command