Alcatel-Lucent 6624, 6648, 6600 Series Viewing Basic Chassis Information, Hardware Information

Page 73

OmniSwitch 6600 Series Chassis and Hardware Components

Viewing Basic Chassis Information

 

 

 

 

Viewing Basic Chassis Information

This section covers the following basic chassis information and monitoring commands:

show hardware info show module

show module long (and show ni) show chassis

show cmm

Important Hardware Status Commands. Additional commands, used to view important hardware status information, are described earlier in this chapter:

For information on viewing primary and back up power supply status, refer to page 2-23.

For information on viewing chassis temperature status, refer to page 2-42.

For information on viewing chassis fan status, refer to page 2-45.

Hardware Information

To view basic hardware information about the switch, enter the show hardware info command at the CLI prompt. This command displays the following information:

CPU type

Flash and RAM memory information

NVRAM battery status

Jumper settings

BootROM and Miniboot versions For example:

-> show hardware info

: PowerPC 8245,

CPU Type

Flash Manufacturer

: SanDisk SDCFB-32

Flash size

: 32505856 bytes (31 MB),

RAM Manufacturer

: DataRam,

RAM size

: 134217728 bytes (128 MB),

NVRAM Battery OK

: YES,

Interrupt Boot Jumper

: ON,

Force UART Defaults Jumper

: ON,

Run Extended Memory Diags Jumper

: ON,

Spare Jumper

: ON,

BootROM Version

: 5.1.2.125,

Backup Miniboot Version

: 5.1.2.125,

Default Miniboot Version

: 5.1.2.125,

Stacked Configurations. For remote sessions (e.g., Telnet and WebView) the show hardware info command displays information for only the primary switch. The command may also be used while connected directly to the primary or secondary switch via the console port. For detailed information on stacked OS6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

OmniSwitch 6600 Series Hardware Users Guide April 2004

page 2-53

Image 73
Contents OmniSwitch 6624/6648 Hardware Users Guide OmniSwitch 6600 Series Hardware Users Guide April Contents Contents Blank Cover Panels Index-1 Unsupported Platforms Supported PlatformsWhat is in this Manual? When Should I Read this Manual?What is Not in this Manual? Who Should Read this Manual?Stage 2 Gaining Familiarity with Basic Switch Functions Stage 1 Using the Switch for the First TimeHow is the Information Organized? Documentation RoadmapAnytime Stage 3 Integrating the Switch Into a NetworkRelated Documentation OmniSwitch 6600 Series Getting Started GuideTechnical Support OmniSwitch 6600 Series Stacked Configurations Stand-Alone and Stacked ConfigurationsStand-Alone Smart Continuous Switching Availability FeaturesHot Swapping Software RollbackHardware Monitoring Automatic MonitoringPort and Fabric Capacities OmniSwitch 6600 Series Fabric CapacitiesUser-Driven Monitoring OS6624/6600-U24 ThroughputSingle Office Building with 1000 Users Application ExamplesOmniPCX Medium Campus with 1500 UsersApplication Examples OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6600 Series Chassis and Hardware Components OmniSwitch 6624 Front Panel OmniSwitchConsole Port 10/100 Ethernet Ports10/100 Ethernet Port Specifications OS6624 SpecificationsOmniSwitch 6600-U24 Console Port Gigabit Ethernet Uplink Module Slot OmniSwitch 6600-U24 Front PanelOS6600-U24 Specifications SFP Mbps Ethernet SFP Port SpecificationsTM OmniSwitch OmniSwitch 6648 Front PanelOS6648 Specifications Front Panel LED Descriptions OS6648 Shown Status LEDsRedundant Power Supply Bay OmniSwitch 6600 Series Rear PanelPower Connector Socket Inline Power Connector Rear PanelOmniSwitch 6600 Series Chassis Top View Mounting the SwitchAirflow Considerations Installing the Switch on a Tabletop or Bench Installation OptionsAttaching a Rack-Mount Flange Attaching the Switch to the RackRack Mounting Stacked Configurations Specifications Power CordsPower Cord Types Grounding the ChassisPower Supply Redundancy Back Up Power SupplyBack Up Power Supply Front Panel Back Up Power Supply SpecificationsBack Up Factory-Installed Primary Power Supply OmniSwitch 6600 Series Redundant AC Circuit ExampleAC Circuit Back Up Factory-Installed Primary Power Supply Redundant AC Circuit RecommendationOrienting the Back Up Power Supply Installing a Back Up Power SupplyHot Swapping Tightening the Captive Screws Inserting the Back Up Power SupplyRemoving the Back Up Power Supply Removing a Back Up Power SupplyLoosening the Captive Screws Blank Cover Panel Requirement Viewing Primary and Back Up Power Supply StatusSlot Number is Specified Viewing Power Supply Status for Stacked ConfigurationsNo Slot Number is Specified OS6600-GNI-U2 Gigabit Ethernet Uplink ModulesOS6600-GNI-U2 Gigabit Ethernet Uplink Front Panel MiniGBIC SlotsOS6600-GNI-U2 Uplink Module Specifications OS6600-GNI-C2 OS6600-GNI-C2 Uplink Module SpecificationsOS6600-GNI-C2 Gigabit Ethernet Uplink Front Panel Copper Gigabit Ethernet PortsHssdc Stacking Connectors Stacking Module SpecificationsStacking Module Stacking Module Front PanelInserting the Uplink or Stacking Module Installing Uplink and Stacking ModulesInstalling Uplink and Stacking Modules Removing Uplink and Stacking Modules Removing the Module Mini Gigabit Interface Converter MiniGBIC Mini Gigabit Interface Converters MiniGBICsMiniGBIC-SX Technical Specifications MiniGBIC SpecificationsMiniGBIC-LX Technical Specifications MiniGBIC-LH-70 Technical SpecificationsInserting the MiniGBIC OS6648 Shown Installing MiniGBICsRemoving MiniGBICs Installed MiniGBIC OS6648 ShownSFP Module Mbps SFPs OS6600-U24SFP-100-LC-MM Technical Specifications Mbps SFP SpecificationsSFP-100-LC-SM15 Technical Specifications SFP-100-LC-SM40 Technical SpecificationsMtrj SFP-100-MTRJ-MM Technical SpecificationsInserting the SFP Installing SFPs OS6600-U24Removing SFPs OS6600-U24 Viewing Chassis Temperature Status Temperature ManagementViewing Temperature Status for Stacked Configurations Temperature Errors Viewing Fan Status Viewing Fan Status for Stacked ConfigurationsNo Slot Number is Specified Right Side Air Intake Vent Chassis AirflowLeft Side Fan Exhaust Vents Air Exhaust. The airflowEffects of Missing Blank Panels on Chassis Airflow Blank Cover PanelsPinouts RS232 Console Port Female DB9 Connector Pinout10/100 Ethernet Port RJ-45 Pinout Copper Gigabit Ethernet Port RJ-45 PinoutTXD RJ-45 Console Port Connector PinoutModifying the Serial Connection Settings Serial Connection Default SettingsConsole Port Serial Connection to the Console PortAdditional table output not shown Hardware Information Viewing Basic Chassis InformationSlot and Component Information Detailed Slot and Component Information Power onGbic IBM Basic Primary Slot and Component Information Basic Chassis Information OmniSwitch 6600 Series MAC Range Specifications Managing MAC Addresses on the SwitchMAC Range Guidelines Base Chassis MAC Address in Stacked Configurations Determining Current MAC Address Allocation on the SwitchBase Chassis MAC Address as Unique Identifier Viewing the Base Chassis MAC AddressThis Chapter Managing OmniSwitch 6600 Series StacksParameter Description Configuration Steps Default Value Specifications and Default ValuesStack Overview Stack Composed of Four OmniSwitch 6648 SwitchesSlot Numbers within a Stack Stacking Resiliency and RedundancyCMM Role Redundancy CMM Roles in a StackCMM Commands Switch PrimaryChassis Management and Monitoring Commands File Management CommandsMemory Monitoring Commands Switch Logging and Monitoring CommandsAssigning Slot Numbers Setting Up a Stacked ConfigurationSEL Button Location Continue to Connecting Cables to Stacking Ports onSlot Numbering Example Stack of Four Switches with Unique Slot NumbersValid Slot Assignments Attaching the Stacking Cable to a Stacking Port Connecting Cables to Stacking PortsRecommended Redundant Connection Between Switches Connecting the Switches in the StackRedundant Stack Connection Connection Failure Between Switches 1Stacking Cable Redundancy Example No Connection FailureVerifying Slot Number Assignments Booting the StackVerifying Primary and Secondary Status for the Stack Idle Status Reloading a Switch with a Primary or Secondary CMM Role Managing Switches in a StackReloading the Switch with the Primary CMM Role Reloading the Switch with the Secondary CMM RoleRestoring Switch Redundancy Synchronizing Switches in a StackModule Behavior During Takeover Changing the Secondary CMM Role to PrimaryResetting All Switches in a Stack Monitoring Stacks Managing and Monitoring OmniSwitch 6600 Series StacksMonitoring Stack Topology Secondary Active Monitoring Stacks Declaration of Conformity CE Mark Regulatory Compliance and Safety InformationSafety and Environmental Standards Safety StandardsStandards Compliance EMC StandardsCanada Class a Statement FCC Class A, PartCISPR22 Class a warning Class a Warning for Taiwan and Other Chinese Markets VcciChassis Lifting Warning Translated Safety WarningsBlank Panels Warning Electrical Storm WarningInvisible Laser Radiation Warning Installation WarningOperating Voltage Warning Lithium Battery WarningProper Earthing Requirement Warning Power Disconnection WarningRestricted Access Location Warning Read Important Safety Information WarningWrist Strap Warning Commit system command Commit file commandCopy flash-synchro command NumericsShow chassis command Show cmm command Show fan command Reload all command Reload commandTakeover command Temp-threshold command