Connections and Wiring
IR/Serial Connections and Wiring
You can connect up to eight IR- or
IR/Serial Connector Wiring Specifications
No. | Port | Signal | Function | |||
|
|
|
|
|
|
|
1 | 8 | GND | Signal GND | |||
|
| Signal 1 (+) | IR/Serial data | |||
|
|
|
|
|
|
|
2 | 9 | GND | Signal GND |
|
| |
| ||||||
|
| Signal 2 (+) | IR/Serial data |
|
| |
|
|
| ||||
|
|
|
|
|
|
|
3 | 10 | GND | Signal GND |
|
| |
|
| |||||
|
| Signal 3 (+) | IR/Serial data |
|
| |
|
|
|
|
|
|
|
4 | 11 | GND | Signal GND | |||
|
| Signal 4 (+) | IR/Serial data | |||
|
|
|
|
|
|
|
5 | 12 | GND | Signal GND | |||
|
| Signal 5 (+) | IR/Serial data | |||
|
|
|
|
|
|
|
6 | 13 | GND | Signal GND | |||
|
| Signal 6 (+) | IR/Serial data | |||
|
|
|
|
|
|
|
7 | 14 | GND | Signal GND | |||
|
| Signal 7 (+) | IR/Serial data | |||
|
|
|
|
|
|
|
8 | 15 | GND | Signal GND | |||
|
| Signal 8 (+) | IR/Serial data | |||
|
|
|
|
|
|
|
Input/Output (I/O) Connections and Wiring
The I/O port responds to switch closures or voltage level (high/low) changes, or can be used for
You can connect up to eight devices to the I/O connectors (port 16). A contact closure between GND and an I/ O port is detected as a Push. When used for voltage inputs, the I/O port detects a low
The PWR pin (+12VDC @ 200 mA) is designed as a power output for the PCS2 or VSS2 (or equivalent). The GND connector is a common ground and is shared by all I/O ports. The following table lists the wiring specifications for the I/O connectors.
I/O Port Wiring Specifications
Pin | Signal | Function |
|
|
|
1 | GND | Signal GND |
|
|
|
2 | I/O 1 | Input/output |
|
|
|
3 | I/O 2 | Input/output |
|
|
|
4 | I/O 3 | Input/output |
|
|
|
5 | I/O 4 | Input/output |
|
|
|
6 | I/O 5 | Input/output |
|
|
|
7 | I/O 6 | Input/output |
|
|
|
8 | I/O 7 | Input/output |
|
|
|
9 | I/O 8 | Input/output |
|
|
|
10 | 12 VDC | PWR |
|
|
|
6 | NXI NetLinx Integrated Controller |