AMX manual NXI Specifications, Ports, Front panel components

Page 6

Product Information

Specifications

NXI Specifications

Power requirements

1.09 A @ 12 VDC (NXI only/no card)

 

 

Memory

64K of IR memory:·

 

• 32K IR memory for IR ports 8-11

 

• 32K IR memory for IR ports 12-15

 

 

Ports:

 

RS-232/422/485 ports (#1-6)

Six RS-232/422/485 control ports with XON/XOFF (transmit on/transmit off),

 

and CTS/RTS (clear to send/ready to send), 300-230,400 baud.

 

Channel range = 1-255

 

• Channels 1-254 provide feedback only.

 

• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a

 

'CTSPSH' command was sent to the port.

Relay port (#7)

12-channel relay port.

 

Channel range = 1-12

IR/Serial ports (#8-15)

8 IR/Serial control ports that support high-frequency carriers up to 1.14 MHz.

 

Channel range = 1-32,767

 

• Channels 1-253 (output): IR commands.

 

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

 

commands).

 

• Channel 255 (feedback): Power status (when IOLink is set).

I/O port (#16)

8-channel I/O port for contact closure, 0-5 VDC voltage sensing, or interac-

 

tive power sensing for IR ports.

 

Channel range = 1-8

 

 

Front panel components:

 

Card slot

Accepts NXC-ME260 NetLinx Master or Hub card.

 

Hub Cards:

 

NXC-NH - Hub Card

 

NXC-HS - Hub Server Card

 

NXC-HE - Hub Expander Card

RS-232/422/485 LEDs

6 sets of red and yellow LEDs light to indicate ports 1-6 are transmitting or

 

receiving RS-232, 422, or 485 data:

 

• TX LEDs (red) blink when transmitting data.·

 

• RX LEDs (yellow) blink when receiving data.

Relay LEDs

12 red LEDs light to indicate relay channels 1-12 are active (closed).

IR/Serial LEDs

8 red LEDs light to indicate IR/Serial channels 1-8 are transmitting control

 

data.

I/O LEDs

 

8 yellow LEDs light when I/O channels 1-8 are active.

 

 

2

NXI NetLinx Integrated Controller

Image 6
Contents NXI AMX Limited Warranty and Disclaimer Table of Contents Table of Contents NXI NetLinx Integrated Controller Product Information Front and Rear Panel ComponentsPorts SpecificationsNXI Specifications Front panel componentsRear Panel Components Product Information NXI NetLinx Integrated Controller Relay Connections and Wiring Installing the Master or Hub CardRS-232/422/485 Wiring Specifications RS-232/422/485 Wiring SpecificationsIR/Serial Connector Wiring Specifications IR/Serial Connections and WiringInput/Output I/O Connections and Wiring Port Wiring SpecificationsUsing the ID Button Structure DEVNumberportsystem Program Port Commands Program Port CommandsPC COM Port Communication Settings Command DescriptionProgram Info Reboot DPSSendcommand PulseESC Pass Codes Escape Pass CodesRS232/422/485 Ports Channels LED Disable/Enable SendCommandsLED SendCommands RS232/422/485 Ports ChannelsRS-232/422/485 SendCommands RS-232/422/485 SendCommandsHsoff SET BaudTset Baud HsonXoff RxonTxclr XONRS-232/422/485 SendString Escape Sequences RS-232/422/485 SendString Escape SequencesIR / Serial Ports 8 15 Channels IR/Serial SendCommandsIR/Serial SendCommands IR / Serial Ports ChannelsCton GET ModeCtof IroffPtof SET ModePON PtonSendcommand DEV, SP,IR OUT Sendcommand IR1, SP,25Xchm XCHZAP LOW Input/Output SendCommandsZAP High GET InputProgramming NXI NetLinx Integrated Controller Programming Enter the Document Name Here It’s Your World Take Control