Agilent Technologies E1364A service manual Environment, Switch Description, Temperature Humidity

Page 16

Environment

The recommended operating environment for the E1364A Switch Module is:

Environment

Temperature

Humidity

 

 

 

Operating

0oC to +55oC

<65% relative (0oC to +40oC)

 

 

 

Storage and

-40oC to +75oC

<65% relative (0oC to +40oC)

Shipment

 

 

 

 

 

Switch Description

NOTE

Switch Specifications

Switch Serial Numbers

Switch Options

The Agilent E1364A Switch Module is an "instrument" in the slots of a VXIbus mainframe. As such, it is assigned an error queue, input and output buffers, and a status register. The switch has 16 channels of Form C relays. Each channel includes a relay with common (C), normally open (NO), and normally closed (NC) contacts.

Instruments are based on the logical addresses of the plug-in modules. See Chapter 1 of the E1364A User’s Manual to set the logical address of the switch module.

Switch module specifications are listed in Appendix A of the E1364A User’s Manual. These specifications are the performance standards or limits against which the instrument may be tested.

Switches covered by this manual are identified by a serial number prefix listed on the title page. Agilent uses a two-part serial number in the form XXXXAYYYYY, where XXXX is the serial prefix, A is the country of origin (A=USA), and YYYYY is the serial suffix. The serial number prefix identifies a series of identical instruments. The serial number suffix is assigned sequentially to each instrument.

The serial number plate is located on the backplane connector. If the serial number prefix of your instrument is greater than the one listed on the title page, a Manual Update (as required) will explain how to adapt this manual to your instrument.

There are no electrical or mechanical options available for the E1364A Switch Module.

16 General Information

Chapter 1

Image 16
Contents Agilent E1364A Channel Form C Switch Module Serial NumbersPage Contents Appendix B. Backdating Information Warranty Limitation Of WarrantyCertification Exclusive RemediesSafety Symbols Documentation HistoryManufacturer’s Name Manufacturer’s AddressDeclares, that the product Product Name Model NumberPage Page Page Agilent E1364A Form C Switch Module IntroductionSafety Considerations General Information ChapterChapter General Information Inspection/Shipping Initial Incoming Inspection GuidelinesPackaging/Shipping Guidelines Temperature Humidity Switch DescriptionEnvironment Recommended Test Equipment Requirements Recommended Model UseGeneral Information Chapter Verification Tests Functional Verification Operation Verification1a. Agilent E1364A Test Fixture Schematic Performance Verification1b. Agilent E1364A Test Fixture Test 2-1 Closed-Channel Resistance Test Normally Closed Resistance Test Next 530 540 END Test 2-2 DC Isolation Test Normally Closed to Chassis 1. Hardware Connections DC Isolation Test NC Channels to Chassis Example DC Isolation Test Verification Tests Chapter Performance Test Record Test Accuracy Ratio TARPerformance Test Record for the E1364A Switch Module Page 1 Performance Test Record for the E1364A Switch Module Page 2 Test Measured Description Minimum Maximum UncertPerformance Test Record for the E1364A Switch Module Page 4 Test Measured Description Minimum Reading Maximum UncertVerification Tests Chapter Part Qty Part Description Replaceable Parts ListsNumber Replaceable Parts Chapter E1364A Terminal Block Replaceable Parts Replaceable Parts Chapter Service Troubleshooting Techniques Identifying the ProblemTesting the Assembly E1364A Tests/Checks Test/Check Reference DesignatorRepair and Maintenance Guidelines ESD PrecautionsVerification Tests C Programs Functional Verification TestPerformance Verification Tests Example Closed Channel Resistance TestClose instrument session Example DC Isolation Test Iclose dm Example C Programs Appendix a Replaceable Parts List Reference Part Qty Part Description Designator NumberPart Number Qty Part DescriptionAgilent E1364A Reference Designators Figure B-1. E1364A Component Assembly Parts Figure B-2. E1364A Terminal Module Replaceable Parts Page Page Copyright Agilent Technologies, Inc