Agilent Technologies E1364A service manual Close instrument session

Page 49

iprintf (id, "CLOS (@%u)\n", channel); ipromptf (dm, "TRIG SGL\n", "%t", reading); printf ("\n Channel %u (closed): %s", i, reading);

iprintf (id, "OPEN (@%u)\n", channel); ipromptf (dm, "TRIG SGL\n", "%t", reading); printf ("\n Channel %u (open): %s", i, reading);

}

printf ("\n\nConnect DMM to NC and C lines of E1364A (4-wire connection)");

getchar ();

iprintf (id, "CLOS (@100:115)\n");

printf ("\n\nContact Resistance -- Normally closed contacts\n");

for (i = 0; i <=15; i++)

{

channel = 100 + i;

iprintf (id, "OPEN (@%u)\n", channel); ipromptf (dm, "TRIG SGL\n", "%t", reading); printf ("\n Channel %u (closed): %s", i, reading);

iprintf (id, "CLOS (@%u)\n", channel); ipromptf (dm, "TRIG SGL\n", "%t", reading); printf ("\n Channel %u (open): %s", i, reading);

}

iclose (id);iclose (dm);

/* Close instrument session */

}

Appendix A

Example C Programs 49

Image 49
Contents Serial Numbers Agilent E1364A Channel Form C Switch ModulePage Contents Appendix B. Backdating Information Limitation Of Warranty WarrantyCertification Exclusive RemediesDocumentation History Safety SymbolsManufacturer’s Address Manufacturer’s NameDeclares, that the product Product Name Model NumberPage Page Page Introduction Agilent E1364A Form C Switch ModuleGeneral Information Chapter Safety ConsiderationsChapter General Information Initial Incoming Inspection Guidelines Inspection/ShippingPackaging/Shipping Guidelines Temperature Humidity Switch DescriptionEnvironment Requirements Recommended Model Use Recommended Test EquipmentGeneral Information Chapter Verification Tests Operation Verification Functional VerificationPerformance Verification 1a. Agilent E1364A Test Fixture Schematic1b. Agilent E1364A Test Fixture Test 2-1 Closed-Channel Resistance Test Normally Closed Resistance Test Next 530 540 END Test 2-2 DC Isolation Test Normally Closed to Chassis 1. Hardware Connections DC Isolation Test NC Channels to Chassis Example DC Isolation Test Verification Tests Chapter Test Accuracy Ratio TAR Performance Test RecordPerformance Test Record for the E1364A Switch Module Page 1 Performance Test Record for the E1364A Switch Module Page 2 Maximum Uncert Test Measured Description MinimumTest Measured Description Minimum Reading Maximum Uncert Performance Test Record for the E1364A Switch Module Page 4Verification Tests Chapter Part Qty Part Description Replaceable Parts ListsNumber Replaceable Parts Chapter E1364A Terminal Block Replaceable Parts Replaceable Parts Chapter Service Identifying the Problem Troubleshooting TechniquesE1364A Tests/Checks Test/Check Reference Designator Testing the AssemblyESD Precautions Repair and Maintenance GuidelinesFunctional Verification Test Verification Tests C ProgramsExample Closed Channel Resistance Test Performance Verification TestsClose instrument session Example DC Isolation Test Iclose dm Example C Programs Appendix a Reference Part Qty Part Description Designator Number Replaceable Parts ListQty Part Description Part NumberAgilent E1364A Reference Designators Figure B-1. E1364A Component Assembly Parts Figure B-2. E1364A Terminal Module Replaceable Parts Page Page Copyright Agilent Technologies, Inc