18.[RUP=]

This command ramps the output volume to a user defined level at a rate defined using the [RAMP] command.

Command Format: [RUP=xxCnUi]

xx = Stop Level (xx = # from 01-32)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume from a starting level of 1 to a level of 20 for the card in slot 4. Send the command [RUP=20C4] and the system will respond with the following feedback:

[02][03][04]…[20]

19.[RDN]

This command ramps the output volume down to a level of 1 at a rate defined using the [RAMP] command.

Command Format: [RDNCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume from a starting level of 32 down to 1 for the card in slot 4. Send the command [RDNC4] and the system will respond with the following feedback:

[31][30][29]…[01]

20.[RDN=]

This command ramps the output volume down to a user defined level at a rate defined using the [RAMP] command.

Command Format: [RDN=xxCnUi]

xx = Stop Level (xx = # from 01-32)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume from a starting level of 32 down to 16 for the card in slot 4. Send the command [RDN=16C4] and the system will respond with the following feedback:

[31][30][29]…[16]

21.[RAMP]

This command displays the ramping time for 32 steps. The time between each step is equal to the time in seconds divided by 32.

Command Format: [RAMPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Display the ramp rate setting for the card in slot 4 by sending the command [RAMPC4]. The system will respond with feedback similar to the following:

RAMPTIME = 6 SECONDS

22.[RAMP=]

This command sets the ramp rate for 32 steps. The settings range from 4 to 18 seconds, in two-second intervals.

Command Format: [RAMP=xCnUi]

x

=

Rate in Seconds

 

 

4

= 0.13 seconds/step

 

 

6

= 0.19 seconds /step

 

 

8

= 0.25 seconds /step

 

 

10

= 0.31 seconds /step

 

 

12

= 0.38 seconds /step

 

 

14

= 0.44 seconds /step

 

 

16

= 0.50 seconds /step

 

 

18

= 0.56 seconds /step

Cn

= Card ID (n = # from 1 to max slots)

Ui

=

Unit ID (i = # from 0 to 9)

400-0095-005

14

14

Image 15 Contents
MT109-100 Table of Contents FCC Notice Precautions / Safety WarningsCleaning GeneralMT109-100 Technical SpecificationsAbout Your MT109-100 MechanicalDescription of MT109-100 Diagram 1 Typical Configuration Application DiagramDiagram 2 Internal View Diagram 3 Jumper Settings MT109-100 as a Master Card Diagram 4 15 IN, 1 OUT Switcher1 RS-232 Interface Installing Your MT109-100Operation RS-232 ControlCnS Description of CommandsCommands VERSaved SEL and SELm STA1STA0 10. +IVLI Volume Ramping FeatureINCREMENT/DECREMENT Format + VLORamp RUP=RDN RDN=MUT0 RSTCLR ONmTest SW Switch31. …F Feedback 32. …P PathSID+ RSISIDn SIDnCiRMG Help42. WR RMCRUP SELVLO VLIMenu Types Menu ModeMenu Command Definitions Using Menu Mode4 MT109-100 Menus Menu Mode ExamplesSet Input 3 Input Volume Set Output VolumeNo Sound Troubleshooting GuideLED is not LIT LED is Blinking REDLimited WARRANTY/RETURN Policies Altinex PoliciesSound Distortion