MULTITASKER™
The output volume line shows the current output volume level and the input level line lists the gain setting for each input,
The mute line shows the output’s status, off or on. A “0” indicates mute is off (output is enabled) and a “1” indicates mute is on (output is disabled).
6.[STA1]
This command enables automatic feedback from the front panel. The command affects any card with
Command Format [STA1]: = On
Feedback Prefix Definitions:
MT | Card model number | |||
VR | Firmware revision | |||
IN | Input selection |
| ||
VO | Output volume level | |||
VI | Input gain settings | |||
VM | Mute setting |
|
| |
Example: |
|
|
| |
Command = | [ON1C4] | |||
Feedback = | (IN1C04) |
| ||
|
| IN | = | Input selection |
|
| 1 | = | Setting |
|
|
|
| Input 1 active |
|
| C04 | = | Card/Slot number |
7.[STA0]
This command disables automatic feedback from the card and front panel. The command affects any card with
Command Format: [STA0]
8.[ +O ]
This command increases the output volume level by 1 up to the maximum level of 32. If the command is sent after a level of 32 has been reached, it will have no effect on the output.
12 |
Command Format: [+OCnUi]
Cn = Card ID
Ui = Unit ID (i = # from 0 to 9)
Example:
Increase the output volume of C4 (slot 4) from 31 to 32 by sending the command [+OC4].
9.[
This command is the same as [+O] except that it decreases the output volume level by 1 down to the minimum level of 1.
10.[ +I ]
This command increases an input level by 1 up to the maximum level of 32. If the command is sent after a level of 32 has been reached, it will have no effect on the input.
Command Format: [+ImCnUi]
m= Input No. (m - # from 1 to 8) Cn = Card ID
Ui = Unit ID (i = # from 0 to 9)
Example:
Increase the output volume of C4 (slot 4) from 31 to 32 by sending the command [+OC4].
11.[
This command is the same as [+Im] except that it decreases an input level by 1 down to the minimum level of 1.
12.[ + ] See the [SEL] command.
13.[ - ] See the [SEL] command.
14.[SEL] and [SELm]
These commands allow the input levels and output volume to be adjusted incrementally.
OUTPUT Command Format: [SELCnUi]
Cn = Card Slot Number
Ui = Unit ID (i = # from 0 to 9)
12