Altinex MT109-100 manual STA1, STA0, 10. +I, SEL and SELm

Page 13

MULTITASKER™

The output volume line shows the current output volume level and the input level line lists the gain setting for each input, 1-8. The maximum input and output values are 32.

The mute line shows the output’s status, off or on. A “0” indicates mute is off (output is enabled) and a “1” indicates mute is on (output is disabled).

6.[STA1]

This command enables automatic feedback from the front panel. The command affects any card with auto-feedback capability, not just the MT109-100.The default at power up, or after a reset is STA0, off. For more details, see the [?Cn] command definition.

Command Format [STA1]: = On

Feedback Prefix Definitions:

MT

Card model number

VR

Firmware revision

IN

Input selection

 

VO

Output volume level

VI

Input gain settings

VM

Mute setting

 

 

Example:

 

 

 

Command =

[ON1C4]

Feedback =

(IN1C04)

 

 

 

IN

=

Input selection

 

 

1

=

Setting (1-8)

 

 

 

 

Input 1 active

 

 

C04

=

Card/Slot number

7.[STA0]

This command disables automatic feedback from the card and front panel. The command affects any card with auto-feedback capability, not just the MT109-100card. The default at power on or reset is STA0, OFF.

Command Format: [STA0]

8.[ +O ]

This command increases the output volume level by 1 up to the maximum level of 32. If the command is sent after a level of 32 has been reached, it will have no effect on the output.

400-0095-005

12

Command Format: [+OCnUi]

Cn = Card ID

Ui = Unit ID (i = # from 0 to 9)

Example:

Increase the output volume of C4 (slot 4) from 31 to 32 by sending the command [+OC4].

9.[ -O ]

This command is the same as [+O] except that it decreases the output volume level by 1 down to the minimum level of 1.

10.[ +I ]

This command increases an input level by 1 up to the maximum level of 32. If the command is sent after a level of 32 has been reached, it will have no effect on the input.

Command Format: [+ImCnUi]

m= Input No. (m - # from 1 to 8) Cn = Card ID

Ui = Unit ID (i = # from 0 to 9)

Example:

Increase the output volume of C4 (slot 4) from 31 to 32 by sending the command [+OC4].

11.[ -I ]

This command is the same as [+Im] except that it decreases an input level by 1 down to the minimum level of 1.

12.[ + ] See the [SEL] command.

13.[ - ] See the [SEL] command.

14.[SEL] and [SELm]

These commands allow the input levels and output volume to be adjusted incrementally.

OUTPUT Command Format: [SELCnUi]

Cn = Card Slot Number

Ui = Unit ID (i = # from 0 to 9)

12

Image 13 Contents
MT109-100 Table of Contents Cleaning Precautions / Safety WarningsGeneral FCC NoticeAbout Your MT109-100 Technical SpecificationsMechanical MT109-100Description of MT109-100 Diagram 1 Typical Configuration Application DiagramDiagram 2 Internal View Diagram 3 Jumper Settings MT109-100 as a Master Card Diagram 4 15 IN, 1 OUT SwitcherOperation Installing Your MT109-100RS-232 Control 1 RS-232 InterfaceCommands Description of CommandsVER CnSSaved STA0 STA110. +I SEL and SELmINCREMENT/DECREMENT Format + Volume Ramping FeatureVLO VLIRDN RUP=RDN= RampCLR RSTONm MUT031. …F Feedback SW Switch32. …P Path TestSIDn RSISIDnCi SID+42. WR HelpRMC RMGVLO SELVLI RUPMenu Command Definitions Menu ModeUsing Menu Mode Menu TypesSet Input 3 Input Volume Menu Mode ExamplesSet Output Volume 4 MT109-100 MenusLED is not LIT Troubleshooting GuideLED is Blinking RED No SoundAltinex Policies Limited WARRANTY/RETURN PoliciesSound Distortion