Altinex 400-0026-004 manual Altinex Homerun Control Program, Connect, Save

Page 20

MATRIX SWITCHERS

end of the cable is connected to the RS-232 port of the HOMERUN Matrix Switcher.

ALTINEX HOMERUN CONTROL PROGRAM

1 Follow Step 1 of previous option.

2.Load the HOMERUN control program on WINDOW 95 from the START UP button, PROGRAM option and Altinex tab.

3Go to the SETUP TAB and verify that current baud rate is set at 2400 baud (default). Then from SET Baud Rate section select 9600 baud and click the program button to program the baud rate into all attached HOMERUN modules.

Note: The HOMERUN Control Software can be downloaded from the Altinex website www.altinex.com in the Download section.

VW=7

VW

set LCD viewing angle

0 through 7

TM

terminal mode

0

TD

turnaround delay

0

BR

baud rate

2

DF

data format

4

HS

handshake

0

LE

local echo

0

EN

line terminator

1

KC

key click

0

KR

key repeat

0

CU

cursor

0

To save changes Press Recall 01.

The OK message will be displayed on the screen for 1 second.

CP-02

DB-9 pin connector

1

2

3

5(short to 6)

6(short to 5)

7

8

9

Signal

description

Power

Ground

Receive

Transmit

CTS (short to pin 6)

DTR (short to pin 5)

Signal

Ground

Power Input

(+5V)

Power Input

(8-12V

regulated)

Connection to

HOMERUN Switcher’s

RS-232 port

Ground

Transmit

Receive

-

-

Ground

-

+12V

1.Turn power to the HOMERUN OFF and back ON. Press the ENTER key.

2.The display will read: Altinex, Inc. 3.2 or the current software version.

Altinex, Inc. 3.2

Congratulations! Your CP-02terminal set up is completed!

A. Power ON:

Turn ON the power to the HOMERUN by plugging in the power cord.

Observe the CP-02going into self-test mode for about 5-6 seconds.

The display will flash the following message:

Vol 1. Test OK

Table 4. CP-02pin outs and connection to HOMERUN Switcher

Terminal Set-up

The CP-02remote terminal must be properly set up before it will operate with the HOMERUN Matrix switcher. To set up the terminal, turn power “ON” while holding the() period button on the keypad, and the terminal will enter into set-up mode. The high contrast liquid crystal display will briefly flash the following message:

The CP-02remote terminal is now ready to control the HOMERUN Matrix Switcher.

B. Function Keys description:

CONNECT

Allows user to make

 

connections between inputs

 

and outputs.

SAVE

Permits the connections

 

between inputs and outputs

19

Image 20
Contents Homerun Series Table of Contents IntroductionPRECAUTIONS/SAFETY Warnings About Your Homerun Matrix Switcher Technical SpecificationsDiagram of FRONT/BACK Panel Matrix Switchers Application Diagram Installing Your Switcher RS-232 port of Homerun Computer or Switcher Control SystemBack Panel Manual Control Reset Selected Channels Press the F1Operation RS-232 Control of the Switcher Programming CommandsPress Function F1+HOLDBAUDn CODEnIkkOmmS IkkOmmAIkkOXXS IkkOXXAIXXOmmS IXXOmmAConnection Command Unit aParameter Unit a Unit B Control Commands ID1 ID2 ID3 ID4IkkOmm IkkOmmPIkkOmmUn IkkOmmUnPIxxoxxx Front Panel Operation Control OperationProgramming Operation Homerun modules Set Baud RateWindows Hyper Terminal Program Save Altinex Homerun Control ProgramConnect Recall SpaceDelete ClearAccessories Optional Control AccessoriesRack Mounting Brackets Table Mount BracketsTroubleshooting Guide CP-01/CP-02/CP-03Limited Warranty Altinex PolicyReturn Policy Contact Information