MATRIX SWITCHERS
| to be saved in any of the 16 |
| available memories. |
RECALL | Allows recalling the saved |
| connections from memory |
| 01 through 16. |
SPACE | Reserved for future use. |
DELETE | Reserved for future use. |
CLEAR | Reserved for future use. |
Recall 01,02,03 | Allows the end user to recall |
| the first three settings by |
| pressing just one button. |
ENTER | To complete and execute a |
| command. |
C. Making Connections:
Making connections with the
1.Press the CONNECT key. IN? will appear on LCD display.
IN:?
2.Enter a two digit INPUT number. For example: to connect input 5, enter: 05 IN: 05 OUT? will appear on the display.
IN:05 OUT?
3.Enter a
IN:05 OUT:11
4.Press the CONNECT key again to enter the next connection.
5.Continue this process until all connections are made.
D.Saving Your Settings:
The
1.Press the SAVE key. SAVE? will appear on the LCD display.
SAVE?
2.Type in a
SAVE? 05
E. Recalling Your Settings:
There are two ways to recall your settings: Quick Recall and Standard Recall. Quick Recall is available for the first three stored configurations. The recall is accomplished by simply pressing the Recall 01, Recall 02 or Recall 03 keys.
1.Press Recall 01 to recall setting stored in memory 01
2.Press Recall 02 to recall setting stored in memory 02
3.Press Recall 03 to recall setting stored in memory 03
Standard Recall is accomplished by pressing the RECALL key and entering a memory number in which a particular setting was stored.
1.Press the RECALL key. RECALL? will appear on LCD display
RECALL?
2.Enter a
RECALL? 05
3.Press the ENTER key.
Note that when the recall function is used, because the settings can include multiple connections, the LED’s on the back of the HOMERUN will not reflect the connections recalled by the memory, but rather the last connection made.
7.5 WINDOWS BASED CONTROL SOFTWARE
This software is available from Altinex website at www.altinex.com, in the Download section.
20