5.Pull the release levers to their unlocked position. This disconnects the CPU module from its backplane. Then pull the CPU module out of the chassis until the locking latch engages. See Figure 4-5.

Locking latch

Figure 4-5. Module Locking Latch

6.Then, with the assistance of another person, push downwards (tower model) or to the right (rack-mount model) on the locking latch and carefully remove the module from the server unit and place it on a flat sturdy surface.

Installing a CPU Module

1.Observe the safety and ESD precautions listed at the beginning of this chapter.

2.Position the locking latches on the front of the CPU module in the unlocked position.

3.With the assistance of another person, support the CPU module with both hands and carefully slide it into the chassis until it is firmly seated in its connector.

4.Push the locking handles all the way their locked position. See Figure 4-6.

CRU Replacement and Server Upgrades 4-9