Error Message

STATUS LED

Suspected

Description

Procedure

Color

Stat

module

 

 

e

 

 

 

CPU0 FAN Alm 01

Amber

Blink

CPU module #1

Cooling fan1 alarm

Check to see if dust is

CPU0 FAN Alm 03

Amber

Blink

CPU module #1

Cooling fan2 alarm

accumulated on the

CPU0 FAN Alm 04

Amber

Blink

CPU module #1

Cooling fan3 alarm

internal fans. Check also if

the fan cables are

 

 

 

 

 

 

 

 

 

 

connected securely. If not

 

 

 

 

 

solved by the above,

 

 

 

 

 

contact your sales agent.

CPU0 offline

Green

Blink

CPU module #1

PCI module logically isolated

Start the PCI module by ft

 

 

 

 

 

sever utility or dismount

 

 

 

 

 

and remount that module.

 

 

 

 

 

If not solved by the above,

 

 

 

 

 

contact your sales agent.

CPU0 removed

Green

Blink

CPU module #1

PCI module detached

Dismount and remount the

 

 

 

 

 

PCI module. If not solved

 

 

 

 

 

by the above, contact your

 

 

 

 

 

sales agent.

CPU0 Temp Alm 00

Amber

Blink

CPU module #1

Temperature alarm (lower limit)

Check to see if dust is

CPU0 Temp Alm 02

Amber

Lit

CPU module #1

Fatal temperature alarm (lower

accumulated on the

 

 

 

 

limit)

internal fans. Check also if

 

 

 

 

 

the fan cables are

CPU0 Temp Alm 07

Amber

Blink

CPU module #1

Temperature alarm (upper limit)

 

connected securely. If not

CPU0 Temp Alm 09

Amber

Lit

CPU module #1

Fatal temperature alarm (upper

solved by the above,

 

 

 

 

 

limit)

contact your sales agent.

 

 

 

 

 

 

 

 

 

 

 

CPU0 VccpAlm 00

Amber

Blink

CPU module #1

CPU operating voltage alarm

Contact your sales agent.

 

 

 

 

(lower limit) (VCCP)

 

CPU0 VccpAlm 02

Amber

Lit

CPU module #1

Fatal CPU operating voltage

 

 

 

 

 

alarm (lower limit) (VCCP)

 

CPU0 VccpAlm 07

Amber

Blink

CPU module #1

CPU operating voltage alarm

 

 

 

 

 

(upper limit) (VCCP)

 

CPU0 VccpAlm 09

Amber

Lit

CPU module #1

Fatal CPU operating voltage

 

 

 

 

 

alarm (upper limit) (VCCP)

 

CPU0 Vtt Alm 00

Amber

Blink

CPU module #1

1.25-V power voltage alarm

 

 

 

 

 

(lower limit)

 

CPU0 Vtt Alm 02

Amber

Lit

CPU module #1

Fatal 1.25-V power voltage

 

 

 

 

 

alarm (lower limit)

 

CPU0 Vtt Alm 07

Amber

Blink

CPU module #1

1.25-V power voltage alarm

 

 

 

 

 

(upper limit)

 

CPU0 Vtt Alm 09

Amber

Lit

CPU module #1

Fatal 1.25-V power voltage

 

 

 

 

 

alarm (upper limit)

 

Problem Solving 5-21

Page 144
Image 144
NEC 320Lb-R manual Suspected Description Procedure Color Stat Module