LED indications | Description | Action |
| Detected a fatal | Contact your sales agent. |
| voltage error. |
|
Amber (blinking | Detected a | If LCD displays some error message, refer to the error |
every 1 second) | temperature error | message list (see Chapter 5). |
| to be warned. | Check if dust is accumulated on internal fans and |
|
| confirm that the fan cables are connected firmly. If the |
|
| message does not disappear, contact your sales |
|
| agent. |
| Detected a voltage | Contact your sales agent. |
| error to be warned. |
|
| Detected a device |
|
| defect. |
|
| Detected a fan | If LCD displays some error message, refer to the error |
| alarm. | message list (see Chapter 5). |
|
| Check if dust is accumulated on internal fans, and |
|
| confirm that the fan cables are connected firmly. If the |
|
| message does not disappear, contact your sales |
|
| agent. |
Red in one module | BMC is being | Wait for a while; it will go off soon. |
| dumped |
|
| PCI module may | Check if PCI module is connected correctly. Look for |
| be connected | loose screws. |
| incorrectly. |
|
| BMC may be out of | BMC firmware may need reprogramming. Contact |
| order. | your sales agent. |
Red in both | Both BMCs are out | Check if both PCI modules are connected correctly. |
modules | of order. | Look for loose screws. If the message does not |
|
| disappear, contact your sales agent. |
Red (blinking every | Revisions to BMC | Contact your sales agent. |
1 second) | firmware don’t |
|
| match. |
|
Red (blinking every | Transfer of synced | Do not loosen a screw on PCI modules or turn off the |
0.5 second) | data after a PCI | AC power before the LED stops blinking. |
| module is replaced |
|
| (this is not an |
|
| error). |
|