2-6 Setting Up the System
After installing the server, open its front door and install the CPU and PCI
modules. For details, see the following section “Installation of Rack-mount
Model.” Procedures are basically the same for the tower model, except that its
modules are mounted vertically instead of horizontally.
IMPORTANT: Follow the procedures below to install the CPU and PCI
modules. Note the following before installing these module.
! Confirm the server is immobilized.
! Place removed modules to the side of the server. Do not place modules on
top of the server.
! It takes at least two people to install the modules; install them slowly and
carefully.
! If the modules do not install smoothly, remove them and try again.
! Install the CPU modules in the right two slots, the PCI modules in the left two
slots. CPU and PCI modules will only install into their proper slots.
! Perform installation starting at the left-most slot.