Problem Solving 5-19
STATUS LED
Error Message Color State Suspected module Description Procedure
Cor1 offline Green Blink PCI module #2 PCI module logically is olated Start the PCI module by ft sever
utility or dismount and remount
that module. If not solved by the
above, contact your sales agent.
Cor1 removed Green Blink PCI module #2 PCI module detached Dismount and remount the PCI
module. If not solved by the
above, contact your sales agent.
Cor1 Temp Alm 00 Amber Blink PCI module #2 Temperature alarm (lower limit)
Cor1 Temp Alm 02 Amber Lit PCI modul e #2 Fatal temperature alarm (lower
limit)
Cor1 Temp Alm 07 Amber Blink PCI module #2 Temperature alarm (upper limit)
Cor1 Temp Alm 09 Amber Lit PCI modul e #2 Fatal temperature alarm (upper
limit)
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.
CPU IERR 00 Green Blink CPU module #1 CPU#1 internal error
CPU IERR 01 Green Blink CPU module #1 CPU#2 internal error
CPU IERR 20 Green Blink CPU module #2 CPU#1 internal error
CPU IERR 21 Green Blink CPU module #2 CPU#2 internal error
CPU T-Trip 00 Green Blink CPU module #1 CPU#1 thermal change error
(upper limit)
CPU T-Trip 01 Green Blink CPU module #1 CPU#2 thermal change error
(upper limit)
CPU T-Trip 20 Green Blink CPU module #2 CPU#1 thermal change error
(upper limit)
CPU T-Trip 21 Green Blink CPU module #2 CPU#2 thermal change error
(upper limit)
CPU0 +12ss Alm
00 Amber Blink CPU module #1 +12-V power voltage alarm (lower
limit)
CPU0 +12ss Alm
02 Amber Lit CPU module #1 Fatal +12-V power voltage alarm
(lower limit)
CPU0 +12ss Alm
07 Amber Blink CPU module #1 +12-V power voltage alarm (upper
limit)
CPU0 +12ss Alm
09 Amber Lit CPU module #1 Fatal +12-V power voltage alarm
(upper limit)
CPU0 +12v Alm 00 Amber Blink CPU module #1 12-V power voltage alarm (lower
limit)
CPU0 +12v Alm 02 Amber Lit CPU modul e #1 Fatal 12-V power voltage alarm
(lower limit)
CPU0 +12v Alm 07 Amber Blink CPU module #1 12-V power voltage alarm (upper
limit)
CPU0 +12v Alm 09 Amber Lit CPU module #1 Fatal 12-V power voltage alarm
(upper limit)
CPU0 +1.5v Alm
00 Amber Blink CPU module #1 1.5-V power voltage alarm (lower
limit)
CPU0 +1.5v Alm
02 Amber Lit CPU modul e #1 Fatal 1.5-V power voltage alarm
(lower limit)
Contact your sales agent.