Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message | Description | Action | ||||
0B22 | CPUs are installed out of order | CPU is faulty. | • | Replace the CPU. | ||
0B28 | Unsupported Processor | The processor (CPU) not | • Install the CPU appropriate to | |||
| detected on Processor 1 | supported by this server is |
| the server. | ||
|
| installed in Processor 1. |
|
| ||
0B29 | Unsupported Processor | The processor (CPU) not | • Install the CPU appropriate to | |||
| detected on Processor 2 | supported by this server is |
| the server. | ||
|
| installed in Processor 2. |
|
| ||
0B30 | CPU FAN #1 Alarm occurred | • Dust obstructing the fan. | • | Replace the fan. | ||
|
| • | Fan is faulty. | • Replace the CPU module | ||
0B31 | CPU FAN #2 Alarm occurred | |||||
• CPU module board is |
| board. | ||||
|
|
| faulty. | • Connect fan cable properly. | ||
0B32 | CPU FAN #3 Alarm occurred | • Dust obstructing the fan. | • | Replace the fan. | ||
|
| • | Fan is faulty. | • Replace the PCI module | ||
|
| • PCI module board is faulty. |
| board. | ||
|
|
|
| • Connect fan cable properly. | ||
0B40 | Invalid System Configuration | • | Configuration error in | • Reset the setting by selecting | ||
| Data |
| SETUP. |
| [Yes] at [Reset Configuration | |
|
| • CPU/PCI module board is |
| Data] | ||
|
|
| faulty. | • Replace the CPU/PCI module | ||
|
|
|
|
| board. | |
0B41 | System Configuration Data | • | Configuration error in | • Reset the setting by selecting | ||
| Read error |
| SETUP. |
| [Yes] at [Reset Configuration | |
|
| • CPU/PCI module board is |
| Data] | ||
|
|
| faulty. | • Replace the CPU/PCI module | ||
|
|
|
|
| board. | |
0B42 | Resource Conflict | Configuration error in | Correct device configuration in | |||
|
| SETUP. | SETUP | |||
|
|
|
| |||
0B43 | Warning: IRQ not configured | Configuration error in | Correct settings in SETUP | |||
|
| SETUP. |
|
| ||
|
|
|
| |||
0B44 | Expansion ROM not initialized | Configuration error in | In SETUP, disable | |||
|
| SETUP. | decompression of expansion | |||
|
|
|
| ROM on unnecessary optional | ||
|
|
|
| PCI cards. | ||
0B45 | System Configuration Data | • | Configuration error in | • Reset the setting by selecting | ||
| Write error |
| SETUP. |
| [Yes] at [Reset Configuration | |
|
| • CPU/PCI module board is |
| Data] | ||
|
|
| faulty. | Replace the CPU/PCI module | ||
|
|
|
| |||
|
|
|
| board. | ||
|
|
|
|
| ||
0B47 | Missing date and time | The date and time are | • | Restart the system. | ||
| synchronization | incorrect due to a | • | |||
|
| communication error |
| SETUP. | ||
|
| between BMCs. | • If the error persists, replace the | |||
|
|
|
|
| PCI module board. | |
0B49 | BMC Issued Reset Command, | • System cannot be reset by | Replace PCI module board. | |||
| but failed System Reset |
| BMC’s reset command. |
|
| |
|
|
|
|
|
| |
0B6E | DIMMs are installed out of | • | DIMM is faulty. | Replace DIMM. | ||
| order |
|
| |||
|
|
|
| |||
0B70 | The error occurred during | • SMBus device is faulty. | • Replace the CPU/PCI module | |||
| temperature sensor reading | • | SMBus is faulty. |
| or front panel board. | |
|
|
|
|
|
| |
0B71 | System temperature out of | • | Fan is faulty. | • | Clean the fan. | |
| Range | • CPU/PCI module board is | • | Replace the fan. | ||
|
|
| faulty. | • Replace the PCI module | ||
|
|
|
|
| board. |