Error Message

STATUS LED

Suspected module

Description

Procedure

Color

State

 

 

 

 

= A =

 

 

 

 

 

 

 

 

 

 

 

AmbientTempAlm00

Amber

Blink

CPU module

Temperature alarm (lower limit)

Contact your sales agent.

AmbientTempAlm02

Amber

Lit

CPU module

Fatal temperature alarm (lower

 

 

 

 

 

limit)

 

AmbientTempAlm07

Amber

Blink

CPU module

Temperature alarm (upper limit)

 

AmbientTempAlm09

Amber

Lit

CPU module

Fatal temperature alarm (upper

 

 

 

 

 

limit)

 

= B =

 

 

 

 

 

 

 

 

 

 

 

BMC Unsync

-

-

PCI module #1

The BMC cannot be synchronized.

Contact your sales agent.

BMC0 Not Ready

Green

Blink

PCI module #1

PCI module’s BMC is disconnected

If disconnection continues for a

BMC1 Not Ready

Green

Blink

PCI module #2

 

while, contact your sales agent.

= C =

 

 

 

 

 

 

 

 

 

 

 

Cor0 +12vAlm 00

Amber

Blink

PCI module #1

12-V power voltage alarm (lower

Contact your sales agent.

 

 

 

 

limit)

 

Cor0 +12vAlm 02

Amber

Lit

PCI module #1

Fatal 12-V power voltage alarm

 

 

 

 

 

(lower limit)

 

Cor0 +12vAlm 07

Amber

Blink

PCI module #1

12-V power voltage alarm (upper

 

 

 

 

 

limit)

 

Cor0 +12vAlm 09

Amber

Lit

PCI module #1

Fatal 12-V power voltage alarm

 

 

 

 

 

(upper limit)

 

Cor0 +2.5vAlm 00

Amber

Blink

PCI module #1

2.5-V power voltage alarm (lower

 

 

 

 

 

limit)

 

Cor0 +2.5vAlm 02

Amber

Lit

PCI module #1

Fatal 2.5-V power voltage alarm

 

 

 

 

 

(lower limit)

 

Cor0 +2.5vAlm 07

Amber

Blink

PCI module #1

2.5-V power voltage alarm (upper

 

 

 

 

 

limit)

 

Cor0 +2.5vAlm 09

Amber

Lit

PCI module #1

Fatal 2.5-V power voltage alarm

 

 

 

 

 

(upper limit)

 

Cor0 +3.3vAlm 00

Amber

Blink

PCI module #1

3.3-V power voltage alarm (lower

 

 

 

 

 

limit)

 

Cor0 +3.3vAlm 02

Amber

Lit

PCI module #1

Fatal 3.3-V power voltage alarm

 

 

 

 

 

(lower limit)

 

Cor0 +3.3vAlm 07

Amber

Blink

PCI module #1

3.3-V power voltage alarm (upper

 

 

 

 

 

limit)

 

Cor0 +3.3vAlm 09

Amber

Lit

PCI module #1

Fatal 3.3-V power voltage alarm

 

 

 

 

 

(upper limit)

 

Cor0 +3.3vsAlm

Amber

Blink

PCI module #1

3.3-V power voltage alarm (lower

 

00

 

 

 

limit)

 

Cor0 +3.3vsAlm

Amber

Lit

PCI module #1

Fatal 3.3-V power voltage alarm

 

02

 

 

 

(lower limit)

 

Cor0 +3.3vsAlm

Amber

Blink

PCI module #1

3.3-V power voltage alarm (upper

 

07

 

 

 

limit)

 

Cor0 +3.3vsAlm

Amber

Lit

PCI module #1

Fatal 3.3-V power voltage alarm

 

09

 

 

 

(upper limit)

 

Cor0 +5.0vAlm 00

Amber

Blink

PCI module #1

5-V power voltage alarm (lower

Contact your sales agent.

 

 

 

 

limit)

 

Cor0 +5.0vAlm 02

Amber

Lit

PCI module #1

Fatal 5-V power voltage alarm

 

 

 

 

 

(lower limit)

 

Cor0 +5.0vAlm 07

Amber

Blink

PCI module #1

5-V power voltage alarm (upper

 

 

 

 

 

limit)

 

Problem Solving 5-15