Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message | Description | Action | ||
0B93 | BMC SDR Repository empty | BMC is faulty. | • Replace the PCI module | |
0B94 | IPMB signal lines do not |
|
| board. |
| respond |
|
|
|
0B95 | BMC FRU device failure |
|
|
|
|
|
|
|
|
0B96 | BMC SDR Repository failure |
|
|
|
|
|
|
|
|
0B97 | BMC SEL device failure |
|
|
|
|
|
|
|
|
0B98 | BMC SEL Overflow | SEL (System Event Log) | • | Clear the SEL. |
|
| overflowed. |
|
|
0BB0 | SMBIOS - SROM data read | • SROM is faulty. | • Replace the front panel board. | |
| error | • Front panel board is faulty. |
|
|
|
|
|
|
|
0BB1 | SMBIOS - SROM data |
|
|
|
| checksum bad |
|
|
|
0BD0 | 1st SMBus device address not | Board is faulty. | • | Check cable connection. |
| acknowledged |
| • | Replace the board. |
|
|
|
|
|
0BD1 | 1st SMBus device Errror |
|
|
|
| detected |
|
|
|
|
|
|
|
|
0BD2 | 1st SMBus timeout |
|
|
|
|
|
|
|
|
0BD3 | 2nd SMBus device address not |
|
|
|
| acknowledged |
|
|
|
|
|
|
|
|
0BD4 | 2nd SMBus device Errror |
|
|
|
| detected |
|
|
|
|
|
|
|
|
0BD5 | 2nd SMBus timeout |
|
|
|
|
|
|
|
|
0BD6 | 3rd SMBus device address not |
|
|
|
| acknowledged |
|
|
|
|
|
|
|
|
0BD7 | 3rd SMBus device Errror |
|
|
|
| detected |
|
|
|
|
|
|
|
|
0BD8 | 3rd SMBus timeout |
|
|
|
|
|
|
|
|
0BD9 | 4th SMBus device address not |
|
|
|
| acknowledged |
|
|
|
|
|
|
|
|
0BDA | 4th SMBus device Error |
|
|
|
| Detected |
|
|
|
|
|
|
|
|
0BDB | 4th SMBus device timeout |
|
|
|
|
|
|
|
|
0BDC | 5th SMBus device address not |
|
|
|
| acknowledged |
|
|
|
|
|
|
|
|
0BDD | 5th SMBus device Error |
|
|
|
| detected |
|
|
|
|
|
|
|
|