Error Message

STATUS LED

Suspected module

Description

Procedure

Color

State

 

 

 

 

Cor0 -12vAlm 09

Amber

Lit

PCI module #1

Fatal -12-V power voltage alarm

Contact your sales agent.

 

 

 

 

(upper limit)

 

Cor0 Bus PERR 01

Green

Blink

PCI module #1

PCI bus parity error

 

Cor0 Bus SERR 01

Green

Blink

PCI module #1

Fatal PCI bus error

 

Cor0 CLK Alm 00

Amber

Blink

CLOCK board

Clock alarm (lower limit)

 

Cor0 CLK Alm 02

Amber

Lit

CLOCK board

Fatal Clock alarm (lower limit)

 

Cor0 CLK Alm 07

Amber

Blink

CLOCK board

Clock alarm (upper limit)

 

Cor0 CLK Alm 09

Amber

Lit

CLOCK board

Fatal Clock alarm (upper limit)

 

Cor0 FAN Alm 01

Amber

Blink

PCI module #1

Cooling fan1 alarm

Check to see if dust is

Cor0 FAN Alm 02

Amber

Blink

PCI module #1

Cooling fan2 alarm

accumulated on the internal

 

 

 

 

 

fans. Check also if the fan

Cor0 FAN Alm 03

Amber

Blink

PCI module #1

Cooling fan3 alarm

cables are connected securely.

Cor0 FAN Alm 04

Amber

Blink

PCI module #1

Cooling fan4 alarm

If not solved by the above,

Cor0 FAN Alm 05

Amber

Blink

PCI module #1

Cooling fan5 alarm

contact your sales agent.

 

 

 

 

 

Cor0 offline

Green

Blink

PCI module #1

PCI module logically isolated

Start the PCI module by ft sever

 

 

 

 

 

utility or dismount and remount

 

 

 

 

 

that module. If not solved by the

 

 

 

 

 

above, contact your sales agent.

Cor0 removed

Green

Blink

PCI module #1

PCI module detached

Dismount and remount the PCI

 

 

 

 

 

module. If not solved by the

 

 

 

 

 

above, contact your sales agent.

Cor0 Temp Alm 00

Amber

Blink

PCI module #1

Temperature alarm (lower limit)

Check to see if dust is

Cor0 Temp Alm 02

Amber

Lit

PCI module #1

Fatal temperature alarm (lower

accumulated on the internal

 

 

 

 

limit)

fans. Check also if the fan

 

 

 

 

 

cables are connected securely.

Cor0 Temp Alm 07

Amber

Blink

PCI module #1

Temperature alarm (upper limit)

 

 

 

 

 

If not solved by the above,

Cor0 Temp Alm 09

Amber

Lit

PCI module #1

Fatal temperature alarm (upper

contact your sales agent.

 

 

 

 

limit)

 

 

 

 

 

Cor1 +12vAlm 00

Amber

Blink

PCI module #2

12-V power voltage alarm (lower

Contact your sales agent.

 

 

 

 

limit)

 

Cor1 +12vAlm 02

Amber

Lit

PCI module #2

Fatal 12-V power voltage alarm

 

 

 

 

 

(lower limit)

 

Cor1 +12vAlm 07

Amber

Blink

PCI module #2

12-V power voltage alarm (upper

 

 

 

 

 

limit)

 

Cor1 +12vAlm 09

Amber

Lit

PCI module #2

Fatal 12-V power voltage alarm

 

 

 

 

 

(upper limit)

 

Cor1 +2.5vAlm 00

Amber

Blink

PCI module #2

2.5-V power voltage alarm (lower

 

 

 

 

 

limit)

 

Cor1 +2.5vAlm 02

Amber

Lit

PCI module #2

Fatal 2.5-V power voltage alarm

 

 

 

 

 

(lower limit)

 

Cor1 +2.5vAlm 07

Amber

Blink

PCI module #2

2.5-V power voltage alarm (upper

 

 

 

 

 

limit)

 

Cor1 +2.5vAlm 09

Amber

Lit

PCI module #2

Fatal 2.5-V power voltage alarm

 

 

 

 

 

(upper limit)

 

Cor1 +3.3vAlm 00

Amber

Blink

PCI module #2

3.3-V power voltage alarm (lower

 

 

 

 

 

limit)

 

Problem Solving 5-17

Page 140
Image 140
NEC 320Lb-R manual Cor0 CLK Alm