Altinex MT110-101 manual Ver, Configuration, Connection Output Volume, CnS

Page 10

MULTITASKER™

The Card ID is a unique identifier. It is equal to the enclosure slot number, or it may be an assigned value. As the slot number, the value can range from 1 to 4 up to 1 to 20 depending on the enclosure. If the value is assigned, the ID may be a maximum of 99.

Card ID 0 (C0) is used for the controller and cannot be reassigned.

The Group ID is a number representing a group of cards defined with the [WR] command. When using the Group ID, all cards in the group will perform the given instruction.

Changing the position of a card will significantly affect the commands recorded on software definitions or third-party control systems.

The Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to zero, each command may be used without Ui. Use the command [SETU0], as explained in the MT100-100 User’s Guide.

Example:

[VERC3]: For Unit ID Zero

[VERC3Ui]: For Unit ID other than Zero

[VERC3]: Equivalent to [VERC3U0]

1.[VER]

This command displays the software version and card type for the card.

Command Format: [VERCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Send the command [VERC4] to check the version of the MT110-103with card ID #4. The system will return the following feedback:

[MT110-103 690-0152-011 C04] MT110-103 = model number 690-0152-011 = software version

C04

= card ID

2.[C]

This command receives the status of the card. Command Format: [CnUi]

Cn = card ID (n = # from 1 to max slots)

Ui = unit id (i = 0 to 9)

Example:

There is an MT110-103card in slot 4. Sending the command [C4] to the MultiTasker™ will yield feedback similar to the following:

CONFIGURATION:

Matrix:8x8, In-Offset=0, Out-Offset=0

CONNECTION

OUTPUT VOLUME

In01-Out01 ON

32/32

In02-Out02 ON

32/32

In01-Out03 ON

32/32

In01-Out04 ON

32/32

In01-Out05 ON

32/32

In01-Out06 ON

32/32

In01-Out07 ON

32/32

In01-Out08 ON

32/32

In this example, Input 1 is connected to all outputs except for Output 2, which is connected to Input 2. All outputs are turned on, or enabled.

The volume level for each output is shown next to its connection. The maximum level is 32 out of 32 which is equal to a gain of one.

If there is no card in slot 4, sending the [C4] command will not return any feedback.

3.[CnS]

This command saves the input to output connections, on/off status and output volume settings for each output. The saved configuration will be restored after the system is reset or powered off, then on.

Command Format: [CnSUi]

Cn = Card ID (n = # from 1 to max slots) S = Save configuration

Ui = Unit ID (i = # from 0 to 9)

400-0197-005

9

Image 10
Contents MT110-101/103 Table of Contents Cleaning Precautions / Safety WarningsInstallation GeneralTechnical Specifications About Your MT110-101/103Description of MT110-101/103 Application Diagram Diagram 1 Typical SetupDiagram 2 MT110-103 Internal View Diagram 3 MT110-101 Internal View Operation Installing Your MT110-101/103Description of Commands RS-232 ControlVER ConfigurationConnection Output Volume CnSSaved MT110-103 card STA1STA0 Group OperationOFF Path OperationFeedback Operation Single Card Operation11. …F Feedback SW Switch10. …S Save 12. …P PathOSO CLROSI FBDSIDn RSISIDnCi RSN Group CommandsSID+ 25. WR28. RD RMGTest Volume Ramping Feature MT110-103 only RUP MT110-103 only Ramptime = 6 Seconds Ramp Time = 16 Seconds MATmXyOSI OFFCLR OSOTroubleshooting Guide Distorted Sound No SoundSound Level is LOW Altinex Policy Limited WARRANTY/RETURN PolicyToll Free 1-800-ALTINEX