Altinex MT110-101 manual RUP MT110-103 only

Page 20

MULTITASKER™

34.[RUP] MT110-103 ONLY

This command ramps the output volume to its maximum level at the rate defined using the [RAMP] command.

Command Format: [RUPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on Output 1 from a starting level of 10 to the maximum level of 32 for the card in slot 8. Send the commands [SEL1C8] then [RUPC8] and the system will respond with the following feedback:

[11][12][13][14]…[32]

35.[RDN] MT110-103 ONLY

This command ramps the output volume down to a level of 00 at a rate defined using the [RAMP] command.

Command Format: [RDNCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on Output 1 from a starting level of 32 down to 00 for the card in slot 8. Send the commands [SEL1C8] then [RDNC8] and the system will respond with the following feedback:

[31][30][29]…[00]

36.[RUPm] MT110-103 ONLY

This command ramps UP the output volume for the specified output on the card. The ramping will continue to its maximum level at the rate defined using the [RAMP] command. The ramping may be stopped at any time using the [RST] command.

Command Format: [RUPmCnUi]

Cn = Card ID (n = # from 1 to max slots)

m = Output No. (n = # from 1 to 8)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume for Output 2 from a starting level of 10 to the maximum level of 32 for the card in slot 8. Send the command [RUP2C8] and the system will respond with the following feedback:

[11][12][13][14]…[32]

37.[RUPm=xx] MT110-103 ONLY

This command ramps a specified output’s volume to a user defined level at a rate defined using the [RAMP] command.

Command Format: [RUPm=xxCnUi]

m= Output No. (m = # from 1-8) xx = Stop Level (xx = # from 01-32)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume on output 7 from a starting level of 1 to a level of 20 for the card in slot 8. Send the command [RUP7=20C8] and the system will respond with the following feedback:

[02][03][04]…[20]

38.[RDNm] MT110-103 ONLY

This command ramps DOWN the output volume for the specified output on the card. The ramping will continue to its minimum level at the

400-0197-005

19

Image 20
Contents MT110-101/103 Table of Contents Precautions / Safety Warnings InstallationCleaning GeneralTechnical Specifications About Your MT110-101/103Description of MT110-101/103 Application Diagram Diagram 1 Typical SetupDiagram 2 MT110-103 Internal View Diagram 3 MT110-101 Internal View Installing Your MT110-101/103 Description of CommandsOperation RS-232 ControlConfiguration Connection Output VolumeVER CnSSaved STA1 STA0MT110-103 card Group OperationPath Operation Feedback OperationOFF Single Card OperationSW Switch 10. …S Save11. …F Feedback 12. …P PathCLR OSIOSO FBDSIDnCi RSISIDn Group Commands SID+RSN 25. WRTest RMG28. RD Volume Ramping Feature MT110-103 only RUP MT110-103 only Ramptime = 6 Seconds Ramp Time = 16 Seconds MATmXyOFF CLROSI OSOTroubleshooting Guide Sound Level is LOW No SoundDistorted Sound Toll Free 1-800-ALTINEX Limited WARRANTY/RETURN PolicyAltinex Policy