Altinex MT110-101 manual Ramp Time = 16 Seconds, MATmXy

Page 22

MULTITASKER™

42.[RAMP=x] MT110-103 ONLY

This command sets the ramp rate for 32 steps. The settings range from 4 to 18 seconds, in two-second intervals.

Command Format: [RAMP=xCnUi]

x

=

Rate in Seconds

 

 

4

= 0.13 seconds/step

 

 

6

= 0.19 seconds /step

 

 

8

= 0.25 seconds /step

 

 

10

= 0.31 seconds /step

 

 

12

= 0.38 seconds /step

 

 

14

= 0.44 seconds /step

 

 

16

= 0.50 seconds /step

 

 

18

= 0.56 seconds /step

Cn

= Card ID (n = # from 1 to max slots)

Ui

=

Unit ID (i = # from 0 to 9)

Example:

There is an MT110-103in slot 5. Send the command [RAMP=16C5] to set the ramp rate to 16 seconds. After this is set, any ramping will occur at a rate of 32 steps in 10 seconds, or

0.50seconds per step. Confirm the setting by sending the command [RAMPC5] and receiving the feedback:

RAMP TIME = 16 SECONDS

43.[MUT0] MT110-103 ONLY

This command turns on the all the outputs without changing the input port selected and without changing any volume settings.

Command Format: [MUT0CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Send the command [MUT0C4] to enable the outputs for the card in slot 4.

44.[MUT1] MT110-103 ONLY

This command turns off all the outputs without changing the input port selected and without changing any output volume settings.

Command Format: [MUT1CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Send the command [MUT1C4] to mute all the outputs for the card in slot 4.

45.[MATmXy]

The matrix command allows the matrix switcher to be setup for different matrix sizes. The following tables show how the inputs and outputs will be configured when the matrix is changed. The input and output layouts are as viewed from the front of the card.

Example:

In the 4x4 configuration, when Input 1 is connected to Output 4, the entire channel, 1a and 1b, will be switched to outputs 4a and 4b respectively.

Command Format: [MATmXyCnUi]

m = number of inputs (m = 8, 4 or 2)

y = number of outputs (y = 8, 4 or 2)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

 

8 x 8

INPUTS

 

OUTPUTS

1

 

1

2

 

2

3

 

3

4

 

4

5

 

5

6

 

6

7

 

7

8

 

8

400-0197-005

21

Image 22
Contents MT110-101/103 Table of Contents Cleaning Precautions / Safety WarningsInstallation GeneralTechnical Specifications About Your MT110-101/103Description of MT110-101/103 Application Diagram Diagram 1 Typical SetupDiagram 2 MT110-103 Internal View Diagram 3 MT110-101 Internal View Operation Installing Your MT110-101/103Description of Commands RS-232 ControlVER ConfigurationConnection Output Volume CnSSaved MT110-103 card STA1STA0 Group OperationOFF Path OperationFeedback Operation Single Card Operation11. …F Feedback SW Switch10. …S Save 12. …P PathOSO CLROSI FBDSIDn RSISIDnCi RSN Group CommandsSID+ 25. WR28. RD RMGTest Volume Ramping Feature MT110-103 only RUP MT110-103 only Ramptime = 6 Seconds Ramp Time = 16 Seconds MATmXyOSI OFFCLR OSOTroubleshooting Guide Distorted Sound No SoundSound Level is LOW Altinex Policy Limited WARRANTY/RETURN PolicyToll Free 1-800-ALTINEX