Altinex MT110-101 manual Clr, Osi, Oso, Fbd

Page 15

MULTITASKER™

Command Format: [ImO*CnUi]

m = Input (m = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Connect Input 1 to all outputs for the MT110-103in slot 5. Send the command [I1O*C5] and Input 1 will be connected to all outputs.

16.[CLR]

This command clears the card, restoring the default settings. In this case, Input 1 to all outputs, all outputs on and all input levels to maximum.

Command Format: [CLRCnUi]

Cn = Group ID (n = # from max slots)

Ui = Unit ID (i = # from 0-9)

Example:

To clear the card in slot 4, send the [CLRC4] command. The card in slot 4 is now set to its default values.

17.[OSI]

This command sets the input offset value that is applied to all inputs. The default is zero, or Input 1 equals Input 1. An offset of 16 would make Input 1 equal to Input 17.

Command Format: [OSImCi]

m = Offset (m = # from 0 to 128)

Ci = Card ID (i = # from 1 to max slots)

Example:

[OSI16C8] sets the input offset value to 16 for the card in slot 8. The inputs on card 8 will now be their physical number plus the offset value. In this case, Input 1 would now be Input 17.

18.[OSO]

This command sets the output offset value that is applied to all outputs. The default is zero, or Output 1 equals Output 1. An offset of 16 would make Output 1 equal to Output 17.

Command Format: [OSOmCi]

m = Offset (m = # from 0 to 128)

Ci = Card ID (i = # from 1 to max slots)

Example:

[OSO16C8] sets the output offset value to 16 for the card in slot 8. The outputs on card 8 will now be addressed by the value of their physical number plus the offset value. In this case, Output 1 would now be Output 17.

19.[FBD]

This command turns feedback delay on or off. It is necessary when installing some newer cards in older systems. If the system does not receive all of the feedback from the card, the card may be communicating too fast. This command will slow down the card's communication rate.

Command Format: [FBDmCnUi]

m= Delay (0= no delay, 1= delay 100mS) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = from 0 to 9)

Example:

The command [HELPC4] is sent to the card in slot 4. Some of the HELP file is displayed on the screen, but most is missing. Send the command [FBD1C4] to slow down the rate at which the card sends feedback to the system.

400-0197-005

14

Image 15
Contents MT110-101/103 Table of Contents General Precautions / Safety WarningsInstallation CleaningAbout Your MT110-101/103 Technical SpecificationsDescription of MT110-101/103 Diagram 1 Typical Setup Application DiagramDiagram 2 MT110-103 Internal View Diagram 3 MT110-101 Internal View RS-232 Control Installing Your MT110-101/103Description of Commands OperationCnS ConfigurationConnection Output Volume VERSaved Group Operation STA1STA0 MT110-103 cardSingle Card Operation Path OperationFeedback Operation OFF12. …P Path SW Switch10. …S Save 11. …F FeedbackFBD CLROSI OSORSI SIDnSIDnCi 25. WR Group CommandsSID+ RSNRMG 28. RDTest Volume Ramping Feature MT110-103 only RUP MT110-103 only Ramptime = 6 Seconds MATmXy Ramp Time = 16 SecondsOSO OFFCLR OSITroubleshooting Guide No Sound Distorted SoundSound Level is LOW Limited WARRANTY/RETURN Policy Altinex PolicyToll Free 1-800-ALTINEX