Altinex MT110-101 manual 10. …S Save, 11. …F Feedback, 12. …P Path, SW Switch, 14. IO, 15. IO

Page 14

MULTITASKER™

If ‘F’ is included, use the [OFFmCnPF] command or the [OFFmCnFP] command.

FEEDBACK OPERATION

After processing a command, an “OK” or “[ERR001]” will be returned as feedback if ‘F’ is included at the end of a command string.

Command Format: [OFF…..F]

Example:

[OFF1C2F]: if path is not set

[OFF1C2PF]: if path is set

10.[…S] – SAVE

This command will save the configuration

command being sent in memory. When sending the command [I1O1C4S], after reset or power up, Input 1 will be connected to Output 1 on C4. This command only saves the Input 1 to Output 1 connection above. In order to save all the current settings, use the [CnS] command.

11.[…F] – FEEDBACK

After processing a command, an “OK” or “[ERR001]” will be returned as feedback if ‘F’ is included at the end of a command string.

12.[…P] – PATH

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in ‘P’ are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See the examples for the [ON] and [OFF] commands.

Example:

There is an MT110-103in slot 4. Input 1 is connected to all outputs and all outputs are on. The PATH command has been used to set Input 2 to Output 1 and turn off Outputs 2 and 3 simultaneously. If checking the status prior to sending the [SW] command, the feedback will appear as follows for the above connection settings:

In01-Out01 ON 32/32 P=02 In01-Out02 ON 32/32 P=OFF

In01-Out03 ON 32/32 P=OFF etc…

The notation "P=" at the end of the line indicates the path condition is active. "P=02" on the Output 1 line indicates that after the [SW] command, Input 2 will be connected to Output 1.

The notation "P=OFF" on lines 2 and 3 indicates that Outputs 2 and 3 will be turned off after the [SW] command is executed.

13.[SW] – SWITCH

This command immediately connects inputs and outputs previously set with the PATH command. The command switches all paths set on this card and all other cards in the enclosure.

Example:

[ON1C4P]

[OFF3C8P]

[SW]

14.[IO]

This command connects a single input to a single output in the current matrix configuration.

Command Format: [ImOxCnUi]

m= Input (m= # from 1 to 8) x = Output (x = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Connect Input 1 to Output 1 for the MT110-103in slot 5. Send the command [I1O1C5] and Input 1 will be connected to Output 1.

15.[IO*]

This command connects a single input to all the outputs in the current matrix configuration.

400-0197-005

13

Image 14
Contents MT110-101/103 Table of Contents Cleaning Precautions / Safety WarningsInstallation GeneralTechnical Specifications About Your MT110-101/103Description of MT110-101/103 Application Diagram Diagram 1 Typical SetupDiagram 2 MT110-103 Internal View Diagram 3 MT110-101 Internal View Operation Installing Your MT110-101/103Description of Commands RS-232 ControlVER ConfigurationConnection Output Volume CnSSaved MT110-103 card STA1STA0 Group OperationOFF Path OperationFeedback Operation Single Card Operation11. …F Feedback SW Switch10. …S Save 12. …P PathOSO CLROSI FBDSIDnCi RSISIDn RSN Group CommandsSID+ 25. WRTest RMG28. RD Volume Ramping Feature MT110-103 only RUP MT110-103 only Ramptime = 6 Seconds Ramp Time = 16 Seconds MATmXyOSI OFFCLR OSOTroubleshooting Guide Sound Level is LOW No SoundDistorted Sound Toll Free 1-800-ALTINEX Limited WARRANTY/RETURN PolicyAltinex Policy