Altinex MT110-101 manual Ramptime = 6 Seconds

Page 21

MULTITASKER™

rate defined using the [RAMP] command. The ramping may be stopped at any time using the [RST] command.

Command Format: [RDNmCnUi]

Cn = Card ID (n = # from 1 to max slots)

m = Output No. (n = # from 1 to 8)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume for output number 8 from a starting level of 32 down to 00 for the card in slot 8. Send the command [RDN8C8] and the system will respond with the following feedback:

[31][30][29]…[00]

39.[RDNm=xx] MT110-103 ONLY

This command ramps a specified output’s volume down to a user defined level at a rate defined using the [RAMP] command.

Command Format: [RDN=xxCnUi]

m= Output No. (xx = # from 1-8) xx = Stop Level (xx = # from 01-32)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume for output number 8 from a starting level of 32 down to 16 for the card in slot 8. Send the command [RDN8=16C8] and the system will respond with the following feedback:

[31][30][29]…[16]

40.[RST] MT110-103 ONLY

This command stops ramping and maintains the last volume setting. It may be used as a stand-alone command, but is designed to be used along with a volume key assignment on the front panel. As a volume key, the ramping action begins when the key is depressed and then stops when the key is released. See the code sample at the beginning of the volume ramping section.

Command Format: [RSTCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

The card in slot 8 is ramping from 1 to 32 at a rate of 32 steps in 18 seconds. Send the command [RSTC8] and the card will stop ramping the output volume. The last displayed volume setting will remain the current volume level.

41.[RAMP] MT110-103 ONLY

This command displays the ramping time for 32 steps. The time between each step is equal to the time in seconds divided by 32.

Command Format: [RAMPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Display the ramp rate setting for the card in slot 8 by sending the command [RAMPC8]. The system will respond with feedback similar to the following:

RAMPTIME = 6 SECONDS

400-0197-005

20

Image 21
Contents MT110-101/103 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralAbout Your MT110-101/103 Technical SpecificationsDescription of MT110-101/103 Diagram 1 Typical Setup Application DiagramDiagram 2 MT110-103 Internal View Diagram 3 MT110-101 Internal View Description of Commands Installing Your MT110-101/103Operation RS-232 ControlConnection Output Volume ConfigurationVER CnSSaved STA0 STA1MT110-103 card Group OperationFeedback Operation Path OperationOFF Single Card Operation10. …S Save SW Switch11. …F Feedback 12. …P PathOSI CLROSO FBDRSI SIDnSIDnCi SID+ Group CommandsRSN 25. WRRMG 28. RDTest Volume Ramping Feature MT110-103 only RUP MT110-103 only Ramptime = 6 Seconds MATmXy Ramp Time = 16 SecondsCLR OFFOSI OSOTroubleshooting Guide No Sound Distorted SoundSound Level is LOW Limited WARRANTY/RETURN Policy Altinex PolicyToll Free 1-800-ALTINEX