Allied Telesis X600-24TS, x600-48Ts VCStackTM Introduction, Features of VCStacking Physical Stack

Page 52

Chapter 2: Virtual Chassis Stacking

VCStackTM Introduction

Features of VCStacking

The Physical Stack

A Virtual Chassis Stack (VCStack) is a group of physically separate switches that are connected so as to function as a single logical switch. In order to function as a VCStack, its component switches are connected using high-speed stacking links.

Switches must be of the same product type to exist within the same stack.

Creating a VCStack (or VCS) greatly eases network management, because you can configure all the stacked devices via a single IP address. Creating a VCS will often eliminate your need to configure protocols such as VRRP and Spanning Tree. VCS also enables you to create highly resilient networks. This resiliency can be applied in several ways.

Within the stack itself, switch interconnection is via two links. The second link is able to provide an alternative data path, thus the stack continues to function if a single link fails. Degraded performance might occur however, due to the reduced VCS bandwidth.

User ports can also be made extremely resilient by utilizing link aggregation. Aggregated links can span ports, modules, and even switches within the stack. Creating aggregated links that span multiple switches within a stack creates an extremely resilient configuration. Communication will still exist even if a switch and its aggregated ports fail.

Depending on the switch types used, a stack can comprise from 2 to 4 individual stack members interconnected via high speed stacking links. A stack always has a primary stack member called the “stack master”, and can contain up to 3 other stack members.

52

Image 52
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Overview Preparation Installing the AT-StackXG Module X600-24Ts-POE Switch List of FiguresFigures List of Tables Tables Preface Product Documentation Starting a Management Session Safety Symbols Used in this Document Symbol Meaning DescriptionWhere to Find Web-based Guides Management Software Updates Contacting Allied TelesisOverview ChapterIntroduction Switch Descriptions LEDsX600-24Ts/XP Switch Shows the x600-24Ts/XP switch front and rear panelShows the x600-48Ts switch front and rear panel X600-48Ts/XP Switch X600-44Ts/XPX600-24Ts-POE Switch X600-24Ts-POE+ Switch Connector Type Speed Duplex Mode Maximum Distance 10/100/1000Base-T PortsCable Type Auto-MDI Port PinoutsSFP Transceiver Slots XFP Transceiver Slots Combo Ports Models Ports and SlotsSD Card Slot Port LEDs 10/100/1000 Base-T LEDsLED SFP LEDs x600-24 Port Switch SFP LEDs x600-48 Port Switch SFP Slot LED Descriptions XFP Transceiver Slot LEDsXFP Slot LED System Status LEDs State DescriptionNon PoE Switch Stack LEDs Stack LEDsMstr Secure Digital SD LED Defined in TableTerminal Port Power Over Ethernet PoE and PoE+ PoE PoE+ Enhanced PoE Differences between PoE, PoE+ and Enhanced PoE Overview Implementation 10/100BASE-TX Redundant Power Supplies AT-RPS3204 Redundant Power Supply UnitAT-LBM Loop Back Module VCS Stacking Module AC Power Connector Overview Virtual Chassis Stacking Features of VCStacking Physical Stack VCStackTM IntroductionVCS Stacking Modules, Cables, and Connections VCStack Recovery States Ring ConfigurationEvent on Master Node Reaction on Reaction on Stack Resiliency Link Configurations via Switch Ports Resilient Stacked Topology Stack Formation Role of the Stack MasterCommon Stack Configuration Stack Member Identification Stack Member Failure Recovery Running QoS within a VCS stackVCS Failure Recovery Fallback ActionStack Maintenance Adding a Stack MemberVirtual Chassis Stacking Installing the Hardware Reviewing Safety Precautions X600 Layer 3 Gigabit Ethernet Switch Installation Guide Installing the Hardware Unpacking a Switch Installing the Power Cord Retaining Clip Installing the Switches in an Equipment Rack ActactivityMounting the Switch in a Rack Resetting the Switch 24Ts/XPVC Stacking Module Installation Installing AT-StackXG Module Securing the AT-StackXG Stacking Module Software Reference Installing the Hardware Cabling the Network Ports Twisted Pair and Fiber Optic Specifications Twisted Pair Cable SpecificationsTransceiver Specifications SFP/XFPInstalling SFP/XFP Transceivers Installing an SFP Transceiver1331 1334 Installing an XFP Transceiver Installing an XFP TransceiverCabling the Network Ports Cabling the 10/100/1000Base-T and Fiber Optic Ports Powering on a Switch Connecting the AC Power CordStarting a Local Management Session Cabling the Network Ports Warranty Registration Cabling the Network Ports Troubleshooting Power LED is Off Twisted Pair Port Link LED is Off SFP or XFP LED is Off Transceiver is Installed but the Status is Not Present System Fault LED is Blinking System Fault LED is Steadily On Cannot Establish a Local Out-of-Band Management Session Switch Functions Intermittently Issues with Virtual Stacking Chassis Configuration Physical Specifications Technical SpecificationsAppendix a Environmental Specifications Power SpecificationsCertifications Pin Signal RJ-45 Twisted Pair Port PinoutsPinout Pair AT-RPS3104 17-pin Connector Pinouts RJ-45 Style Serial Terminal Port PinoutsPin Definition AT-RPS3204 21-pin D-combo Port and Connector Pinouts Pin Appendix a Technical Specifications 112
Related manuals
Manual 72 pages 26.86 Kb Manual 110 pages 37.26 Kb