Allied Telesis X600-24TS-POE+, x600-48Ts, x600-24Ts/XP, x600-24Ts-POE SFP LEDs x600-24 Port Switch

Page 33

x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide

Table 3. Base-T LED Descriptions (Continued)

LED

Function

State

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

There is no powered device detected.

 

 

 

 

 

 

Solid

The end-node is a powered device

 

Power over

Green

and the port is providing power to it.

PoE2

Ethernet

 

 

Solid

The port is experiencing a problem

Status

 

Amber

providing PoE to the end-node.

 

 

 

 

 

 

 

 

Flashing

The port is connected to a powered

 

 

Amber

device but providing power to it would

 

 

 

exceed the maximum PoE power

 

 

 

budget of the switch.

 

 

 

 

1.The Duplex Mode and Collisions LED is present on all the x600 switches except for the x600-24Ts-POE and x600-24Ts-POE+ switches.

2.The PoE LED is only present on the x600-24Ts-POE and x600-24Ts-POE+ switches.

SFP LEDs There is one LINK/ACTIVITY LED for each SFP slot. The SFP LEDs for the x600 24 port switches are shown in Figure 14. The SFP LEDs for the x600 48 port switches are shown in Figure 15 on page 34. The LED definition are given in Table 4 on page 34

SFP

L/A

21

22

23 24

161

Figure 14. SFP LEDs - x600-24 Port Switch

33

Image 33
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Overview Preparation Installing the AT-StackXG Module List of Figures X600-24Ts-POE SwitchFigures List of Tables Tables Preface Product Documentation Starting a Management Session Symbol Meaning Description Safety Symbols Used in this DocumentWhere to Find Web-based Guides Contacting Allied Telesis Management Software UpdatesChapter OverviewIntroduction LEDs Switch DescriptionsShows the x600-24Ts/XP switch front and rear panel X600-24Ts/XP SwitchShows the x600-48Ts switch front and rear panel X600-44Ts/XP X600-48Ts/XP SwitchX600-24Ts-POE Switch X600-24Ts-POE+ Switch 10/100/1000Base-T Ports Connector Type Speed Duplex Mode Maximum DistancePort Pinouts Cable Type Auto-MDISFP Transceiver Slots XFP Transceiver Slots Models Ports and Slots Combo PortsSD Card Slot 10/100/1000 Base-T LEDs Port LEDsLED SFP LEDs x600-24 Port Switch XFP Transceiver Slot LEDs SFP LEDs x600-48 Port Switch SFP Slot LED DescriptionsXFP Slot LED State Description System Status LEDsStack LEDs Non PoE Switch Stack LEDsMstr Defined in Table Secure Digital SD LEDTerminal Port Power Over Ethernet PoE and PoE+ PoE PoE+ Enhanced PoE Differences between PoE, PoE+ and Enhanced PoE Overview Implementation 10/100BASE-TX AT-RPS3204 Redundant Power Supply Unit Redundant Power SuppliesAT-LBM Loop Back Module VCS Stacking Module AC Power Connector Overview Virtual Chassis Stacking VCStackTM Introduction Features of VCStacking Physical StackVCS Stacking Modules, Cables, and Connections Ring Configuration VCStack Recovery StatesEvent on Master Node Reaction on Reaction on Stack Resiliency Link Configurations via Switch Ports Resilient Stacked Topology Role of the Stack Master Stack FormationCommon Stack Configuration Stack Member Identification Running QoS within a VCS stack Stack Member Failure RecoveryFallback Action VCS Failure RecoveryAdding a Stack Member Stack MaintenanceVirtual Chassis Stacking Installing the Hardware Reviewing Safety Precautions X600 Layer 3 Gigabit Ethernet Switch Installation Guide Installing the Hardware Unpacking a Switch Installing the Power Cord Retaining Clip Actactivity Installing the Switches in an Equipment RackMounting the Switch in a Rack 24Ts/XP Resetting the SwitchVC Stacking Module Installation Installing AT-StackXG Module Securing the AT-StackXG Stacking Module Software Reference Installing the Hardware Cabling the Network Ports Twisted Pair Cable Specifications Twisted Pair and Fiber Optic SpecificationsSFP/XFP Transceiver SpecificationsInstalling an SFP Transceiver Installing SFP/XFP Transceivers1331 1334 Installing an XFP Transceiver Installing an XFP TransceiverCabling the Network Ports Cabling the 10/100/1000Base-T and Fiber Optic Ports Connecting the AC Power Cord Powering on a SwitchStarting a Local Management Session Cabling the Network Ports Warranty Registration Cabling the Network Ports Troubleshooting Power LED is Off Twisted Pair Port Link LED is Off SFP or XFP LED is Off Transceiver is Installed but the Status is Not Present System Fault LED is Blinking System Fault LED is Steadily On Cannot Establish a Local Out-of-Band Management Session Switch Functions Intermittently Issues with Virtual Stacking Chassis Configuration Technical Specifications Physical SpecificationsAppendix a Power Specifications Environmental SpecificationsCertifications RJ-45 Twisted Pair Port Pinouts Pin SignalPinout Pair RJ-45 Style Serial Terminal Port Pinouts AT-RPS3104 17-pin Connector PinoutsPin Definition AT-RPS3204 21-pin D-combo Port and Connector Pinouts Pin Appendix a Technical Specifications 112