All Countries: Install product in accordance with local and National Electrical Codes.  E8

Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.  E21

Caution: Risk of explosion if battery is replaced by an incorrect type. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Attention: Le remplacement de la batterie par une batterie de type incorrect peut provoquer un danger d’explosion. La remplacer uniquement par une batterie du même type ou de type équivalent recommandée par le constructeur. Les batteries doivent être éliminées conformément aux instructions du constructeur.  E22

Warning: Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading.  E25

If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).  E35

Caution: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.  E36

Warning: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips).  E37

Warning: To reduce the risk of electric shock, the PoE ports on this product must not connect to cabling that is routed outside the building where this device is located.  E40

67

Image 67
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Overview Preparation Installing the AT-StackXG Module List of Figures X600-24Ts-POE SwitchFigures List of Tables Tables Preface Product Documentation Starting a Management Session Symbol Meaning Description Safety Symbols Used in this DocumentWhere to Find Web-based Guides Contacting Allied Telesis Management Software UpdatesChapter OverviewIntroduction LEDs Switch DescriptionsShows the x600-24Ts/XP switch front and rear panel X600-24Ts/XP SwitchShows the x600-48Ts switch front and rear panel X600-44Ts/XP X600-48Ts/XP SwitchX600-24Ts-POE Switch X600-24Ts-POE+ Switch 10/100/1000Base-T Ports Connector Type Speed Duplex Mode Maximum DistancePort Pinouts Cable Type Auto-MDISFP Transceiver Slots XFP Transceiver Slots Models Ports and Slots Combo PortsSD Card Slot 10/100/1000 Base-T LEDs Port LEDsLED SFP LEDs x600-24 Port Switch XFP Transceiver Slot LEDs SFP LEDs x600-48 Port Switch SFP Slot LED DescriptionsXFP Slot LED State Description System Status LEDsStack LEDs Non PoE Switch Stack LEDsMstr Defined in Table Secure Digital SD LEDTerminal Port Power Over Ethernet PoE and PoE+ PoE PoE+ Enhanced PoE Differences between PoE, PoE+ and Enhanced PoE Overview Implementation 10/100BASE-TX AT-RPS3204 Redundant Power Supply Unit Redundant Power SuppliesAT-LBM Loop Back Module VCS Stacking Module AC Power Connector Overview Virtual Chassis Stacking VCStackTM Introduction Features of VCStacking Physical StackVCS Stacking Modules, Cables, and Connections Ring Configuration VCStack Recovery StatesEvent on Master Node Reaction on Reaction on Stack Resiliency Link Configurations via Switch Ports Resilient Stacked Topology Role of the Stack Master Stack FormationCommon Stack Configuration Stack Member Identification Running QoS within a VCS stack Stack Member Failure RecoveryFallback Action VCS Failure RecoveryAdding a Stack Member Stack MaintenanceVirtual Chassis Stacking Installing the Hardware Reviewing Safety Precautions X600 Layer 3 Gigabit Ethernet Switch Installation Guide Installing the Hardware Unpacking a Switch Installing the Power Cord Retaining Clip Actactivity Installing the Switches in an Equipment RackMounting the Switch in a Rack 24Ts/XP Resetting the SwitchVC Stacking Module Installation Installing AT-StackXG Module Securing the AT-StackXG Stacking Module Software Reference Installing the Hardware Cabling the Network Ports Twisted Pair Cable Specifications Twisted Pair and Fiber Optic SpecificationsSFP/XFP Transceiver SpecificationsInstalling an SFP Transceiver Installing SFP/XFP Transceivers1331 1334 Installing an XFP Transceiver Installing an XFP TransceiverCabling the Network Ports Cabling the 10/100/1000Base-T and Fiber Optic Ports Connecting the AC Power Cord Powering on a SwitchStarting a Local Management Session Cabling the Network Ports Warranty Registration Cabling the Network Ports Troubleshooting Power LED is Off Twisted Pair Port Link LED is Off SFP or XFP LED is Off Transceiver is Installed but the Status is Not Present System Fault LED is Blinking System Fault LED is Steadily On Cannot Establish a Local Out-of-Band Management Session Switch Functions Intermittently Issues with Virtual Stacking Chassis Configuration Physical Specifications Technical SpecificationsAppendix a Power Specifications Environmental SpecificationsCertifications RJ-45 Twisted Pair Port Pinouts Pin SignalPinout Pair RJ-45 Style Serial Terminal Port Pinouts AT-RPS3104 17-pin Connector PinoutsPin Definition AT-RPS3204 21-pin D-combo Port and Connector Pinouts Pin Appendix a Technical Specifications 112