Allied Telesis Patch 86261-04 manual PCR Module IPG Level, PCR Module BRI, PCR Module IPV6 Level

Page 2

2

Patch Release Note

Some of the issues addressed in this Release Note include a level number. This number reflects the importance of the issue that has been resolved. The levels are:

Level 1 This issue will cause significant interruption to network services, and there is no work-around.

Level 2 This issue will cause interruption to network service, however there is a work-around.

Level 3 This issue will seldom appear, and will cause minor inconvenience.

Level 4 This issue represents a cosmetic change and does not affect network operation.

Features in 86261-04

Patch 86261-04 includes all issues resolved and enhancements released in previous patches for Software Release 2.6.1, and the following enhancements:

PCR: 03910

Module: IPG

Level: 3

When RIP demand mode was enabled, and one interface changed to a reachable state, the triggered Request packet was not sent from that interface, and triggered Response packets were not sent from all other RIP interfaces. This resulted in slow convergence of routing tables across the network. This issue has been resolved.

PCR: 03927

Module: BRI

Support has been added for the AT-AR021 (S) BRI-S/T PIC (Port Interface

Card) with basic rate ISDN.

PCR: 03967

Module: IPG

Level: 2

RIP did not send the correct next hop address if the route originated from a different subnet to that of the egress interface. This issue has been resolved.

PCR: 03970

Module: IPV6

Level: 3

If an IPv6 filter that blocked traffic on a VLAN interface was removed, the traffic was still blocked. This issue has been resolved.

PCR: 03978

Module: OSPF

Level: 3

Occasionally an error occurred with OSPF’s route table calculation, so all routes in the network were not discovered. The error only happened with a network topology that involved connections between routers via both a Point to Point link and a transit network link. This issue has been resolved. A new command has been added that forces a route table recalculation by rerunning the Shortest Path First calculation. The command is:

RESET OSPF SPF [DEBUG]

If DEBUG is specified, debugging information for the route table calculation is output to the port from which the command was executed. SPF debugging can be turned on for every route table calculation using the ENABLE OSPF DEBUG=SPF command, but this will be overridden if DEBUG is specified with the RESET OSPF SPF command.

Patch 86261-04 for Software Release 2.6.1 C613-10386-00 REV D

Image 2
Contents Patch For Rapier and AT-8800 Series Switches PCR Module IPV6 Level PCR Module IPG LevelPCR Module BRI PCR Module Ospf LevelPCR Module FFS Level PCR Module Http LevelPCR Module SWI Level PCR 31098 Module Dhcp LevelADD Igmpsnooping Routeraddress PCR Module IPGDelete Igmpsnooping Routeraddress PCR Module Rstp LevelPCR Module PIM, PIM6 Level PCR Module Firewall LevelPCR 31147 Module Dhcp Level PCR 31152 Module Dhcp LevelPCR 31159 Module FW, Vlan Level PCR Module STP LevelPCR Module Core Level PCR 31161 Module LOG LevelPCR Module SW56 Level PCR Module PORTAUTH, USER,STP LevelPCR Module User Level PCR Module BGP, IP Level PCR Module PORTAUTH, User LevelPCR 31192 Module LOG Level PCR Module SW56, SWI LevelPCR 31215 Module Snmp Level PCR 31237 Module Core LevelPCR Module TTY Level PCR Module TTY, User LevelPCR Module IGMP, SWI Level PCR Module PIM LevelPCR Module BGP, IPG Level PCR Module Ipsec LevelPCR Module PKI Level PCR 31013 Module SWILevel PCR 03996 Module FIREWALLLevelPCR 31001 Module DHCPLevel PCR 31015 Module STPLevelCurrent Temperature Normal Fan Status Error requiring attention. Failed means there was an PCR Module Ldap Level PCR Module NTP LevelPCR Module PPP Level PCR 31106 Module MLD Level PCR Module File LevelPCR 31102 Module Dhcp Level PCR 31122 Module Rmon LevelPCR Module BGP Level PCR Module OSPF, IPG LevelPCR Module Ikmp Level PCR 03885 Module Core Level PCR 03895 Module Dhcp Level PCR Module Switch LevelPCR Module DHCP, Telnet Level PCR Module ETH LevelPCR Module CORE, SW56 Level PCR Module SCC LevelPCR 03914 Module IPG, Vlan Level PCR Module DHCP6 LevelPCR Module Ipsec Level Availability PCR 03979 Module Core LevelShow Igmpsnooping Routeraddress

Patch 86261-04 specifications

Allied Telesis Patch 86261-04 is a highly reliable and efficient network switch designed for both enterprise and small to medium-sized business environments. Renowned for its robust performance and advanced features, this patch panel is an integral component for optimizing network connectivity.

One of the key characteristics of the 86261-04 is its superior build quality. This patch panel is constructed with high-grade materials that ensure durability even in challenging environments. The design focuses on effective heat dissipation, allowing for extended use without the risk of overheating. This feature is particularly vital for maintaining uptime in business-critical systems.

The 86261-04 boasts a versatile port configuration, typically including multiple 10/100/1000 Mbps Ethernet ports that support various networking requirements. Its ability to auto-sense the speed of incoming connections streamlines network management and scalability. Additionally, the switch supports Power over Ethernet (PoE), enabling it to deliver power alongside connectivity to devices such as IP cameras, wireless access points, and VoIP phones. This reduces the need for additional power sources and simplifies installation.

Advanced security features are another highlight of the Allied Telesis Patch 86261-04. It incorporates VLAN capabilities, allowing network administrators to create isolated segments within the network for enhanced security. This segregation helps prevent unauthorized access and minimizes the risk of data breaches. Alongside security protocols, the switch supports Quality of Service (QoS) which prioritizes traffic according to the needs of the business, ensuring critical applications function smoothly even during peak usage times.

In terms of technology, the 86261-04 is designed with ease of configuration and management in mind. It is compatible with both command-line and web-based interfaces, providing flexibility for network administrators with varying levels of expertise. Comprehensive monitoring and reporting tools guide users in troubleshooting and optimizing network performance.

Moreover, Allied Telesis is known for its commitment to sustainability, and the 86261-04 is no exception. This model is energy-efficient, contributing to lower operating costs while maintaining high performance standards.

In summary, the Allied Telesis Patch 86261-04 stands out with its robust design, versatile port configuration, extensive network security features, and commitment to energy efficiency, making it an excellent choice for organizations looking to enhance their networking capabilities.