Chapter 2 Monitoring the System
Monitoring a UPS
Step 2 If any of the following devices are not turned on, power them on as follows:
•
•Cisco ICS
•Catalyst
Step 3 Complete the procedure that is appropriate for the type of UPS connection that you made in Step 1:
• | SAP Card COM1 |
| Through a Serial Connection” on page |
• | Ethernet |
| an Ethernet Connection” on page |
|
|
Configuring the System to Monitor the UPS Through a Serial Connection
If the UPS serial port is connected to the SAP card COM1 port on the
Cisco ICS 7750, complete the following steps to configure the UPS so that the Cisco ICS 7750 can monitor UPS status:
Step 1 On the PC, choose Start > Run.
Step 2 Open a Telnet session with the SPE running System Manager: telnet IP address 5000
Step 3 Log in as an administrator (userID administrator), and enter your password (the default is changeme).
Step 4 Enter the following command to stop the FMMServer on the SPE:
net stop FmmServer
Step 5 Change to the FMM directory:
cd Program Files\Cisco Systems\ics\FMM
| Cisco ICS 7750 Administration and Troubleshooting Guide |