SC3100
Installation
The RF bulkhead connector, on the end of the factory supplied coaxial cable, may be installed directly on the host alarm panel enclosure by using one of the following methods:
1.An existing
2.A ½ in. diameter hole, carefully drilled into the top of the host alarm panel enclosure.
3.The 2" x 2" factory supplied antenna mounting
Use the 1.5 inch diameter antenna mounting washers (P/N
If a remote antenna location is required, mount the antenna in a suitable location as best determined by the results of IT1500 Tester. Use the
For remote antenna installations, Bosch Security Systems recommends using
4.3Connecting Wires to the SC3100
Refer to the following illustration of the SAFECOM SC3100 Radio Communicator:
1 | 2 | 3 | 4 |
SAFECOM
SYSTEM RADIO
RJ31-X DIALER
Figure 5: SC3100
4.3.1Dialer
Connect the alarm panel Tip and Ring to this connector. The SC3100 DIALER connector is an 8 pin RJ31X compatible female modular jack.
4.3.2R131X
Connect the premises RJ31X telephone jack to this connector. The SC3100 RJ31X connector is an
4.3.3Main Molex Connector
The SC3100 Main Molex connector is to be installed with the factory supplied 6 conductor wiring harness. This wiring harness contains the wires necessary for connecting the 12 VDC power source. The wires are identified as described in the following paragraph.
The following wires are supplied with the SAFECOM SC3100 wiring harness:
•Black
VDC SUPPLY.
•Red (+) 12 VDC: Connect the red wire to the positive (+) side of the 12 VDC power source.
Note: The SC3100 is shipped from the factory with the internal 12V DC battery installed, but not connected. The battery might not be at full capacity after an idle,
| SC3100 Operation and Installation Guide |
|
|
| |
Page 20 | © 2004 Bosch Security Systems |