Bosch Appliances SC3100 manual 90026-201D Bosch Security Systems

Page 24

SC3100

System Initialization

30= Long 2300 Hz ACK Tone, Any digital pulse type format. 31= Long 2300 Hz ACK Tone, Radionics BFSK.

32= Long 2300 Hz ACK Tone, 0-2 pulse type format.

33= Long 2300 Hz ACK Tone, 0-2 pulse type format with parity. 34= Long 2300 Hz ACK Tone, 3+1 pulse type format

35= Long 2300 Hz ACK Tone, 3+1 pulse type format with parity. 36= Long 2300 Hz ACK Tone, 4+2 pulse type format

37= Long 2300 Hz ACK Tone, 4+2 pulse type format with parity. 38= Long 2300 Hz ACK Tone, FBI Superfast (DTMF)

40= 1400 Hz long ACK Tone, Any digital pulse type format. 41= 1400 Hz long ACK Tone, Radionics BFSK.

42= 1400 Hz long ACK Tone, 0-2 pulse type format.

43= 1400 Hz long ACK Tone, 0-2 pulse type format with parity. 44= 1400 Hz long ACK Tone, 3+1 pulse type format

45= 1400 Hz long ACK Tone, 3+1 pulse type format with parity. 46= 1400 Hz long ACK Tone, 4+2 pulse type format

47= 1400 Hz long ACK Tone, 4+2 pulse type format with parity. 48= 1400 Hz long ACK Tone, FBI Superfast (DTMF)

80= Any ADEMCO DTMF format (4+2 Express, ADEMCO High Speed, Contact ID) 81= SIA (RELAXED ONLY)

82= Radionics Modem II (D4112, D6112, D7112, D8112 and equivalent) 83= Radionics Modem 11E (D7212, D9112, and equivalent)

84= Special Contact ID format for Security Dimensions & Australian made alarm panels (NESS, EDM, Solutions, Concepts).

Digital XLAT: 0 to 8: The Digital Translation Table (XLAT) parameter tells the SAFECOM SC9000 computer where to look up alarm signals. The translation table (XLAT) gives the operator the ability to assign a table, and then build the table so that usually cryptic alarm signals like “31” will be looked up, in the translation table (XLAT) assigned, and given a brief English text definition like, “BURG Z1”. This can be very useful in the unlikely event of an automation failure. The translation table (XLAT) can allow the Central Station Operators to process alarms from the SAFECOM SC9000 directly without looking up codes to understand them. The translation text assigned to the Alarm Event Code is ONLY for display in the SAFECOM SC9000 computer and is NOT part of the Alarm message sent to the Automation software. Each Digital Translation (XLAT) table in the SAFECOM computer has 240 possible entries for alarm event code to text translation/definition. A maximum of 8 characters are available for each alarm event code translation/definition. If “0” is selected for the translation table (XLAT) then all alarm signals from this specific account will be displayed exactly as they are transmitted by the host alarm panel without any translation/ definition.

Note: The Digital Translation (XLAT) parameter does not have to be set for the SC3100 to operate properly.

5.2Establishing Communications with the Central Station SAFECOM SC9000 Computer

To establish radio communications between an SC3100 in the field and the Central Station:

1.Ensure the correct S/N, PID #, Framer #, and RF Channel are entered in the SC3100’s account in the SAFECOM computer.

Note: The SC9000 computer is located at the Central Station.

2.Connect the positive (+ red) and negative (- black) wires from the SC3100’s Power Molex connector to the host alarm panel auxiliary power source. Power On.

3.The Radio Status LED on the SC3100 should illuminate red (TX) and green (RX) to indicate that the SC3100 Radio Communicator is transmitting and receiving. If the Radio LED does not illuminate red to indicate that the system is transmitting after system Power On, a hardware component failure is possible. When the SC3100 system detects a hardware failure, the System Status LED on the SC3100 will illuminate

 

SC3100 Operation and Installation Guide

 

 

 

90026-201D

Page 24

© 2004 Bosch Security Systems

Image 24
Contents Operation and Installation Guide SC3100 Radio CommunicatorSC3100 Contents Contents Introduction Safecom Telemetry Communications System Safecom Communications PathsIntroduction Overview of Safecom Radio CommunicatorsSC3100, Full Data Transfer, Radio Communicator Safecom SC3100 Radio Communicator Specifications Standard Radio SpecificationsFederal Communications Commission FCC Statement Federal Communications Commission FCC Notice To UsersSC3100 SC3100 Circuit Board SC3100 Circuit Board ComponentsSystem Status LED Indications Radio Status LED Indications SC3100 Pre-Installation Requirements SC3100 Pre-Installation RequirementsSC3100 Wiring Requirements DC Power Requirements of the SC3100 Radio CommunicatorSC3100 Radio Communicator Location Antenna LocationSC3100 Acceptable Antenna Types SC3100 Antenna TypesSC3100 Installation Installation Procedures SC3100 Radio CommunicatorAntenna Installation Connecting Wires to the SC3100Main Molex Connector 2 R131XSystem Initialization Procedures System InitializationProgramming Parameters Dialer ACK Dialer FormatDigital Format 90026-201D Bosch Security Systems Manual Initialization of an SC3100 Radio Communicator SC3100 SC3100 Programming Worksheet Warranty Limited Warranty Warranty Coverage and DurationWhat this Warranty does not Cover How to Receive Warranty ServiceSC3100 SC3100