data booster and can each be up to 30 metres away from the next SmartView. The channel can be selected on remote SmartView units using an extension of the HOTKEY control function.
For example, consider a situation where two SmartView 4 port units are connected together as shown below. To connect to the computer attached to port 3 on SmartView B the user would hold down the hotkey keys then press ‘2’ followed by ‘3’, whilst keeping the hotkey keys pressed. This will have the effect of connecting to port 3 of the SmartView which is connected into port 2 of the first SmartView unit A.
For example to connect to port 3 on the SmartView cascaded off port 2 of your first SmartView use:
press ba2release 2
press 3release 3ba
A typical cascade of two SmartView 4 port units
When cascading SmartViews you should ensure that all the SmartViews are set to use the same cascade query code (see section 4.8).