Figure 9:
4.2.2 DC Power Supply Wiring Examples
DC Power supply wiring examples
NOTES: |
|
1. | |
| installed within 3m of unit. |
2. | A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies. |
3. | Equipment must be installed according to the applicable country wiring codes. |
4. | When equipped with two HI voltage power supplies, independent AC sources can be |
| used to power the product for greater redundancy. However, separate circuit breakers |
| must be installed and separately identified. |
5. | When equipped with two DC voltage power supplies |
| DC sources may be used to power the product for greater redundancy. However, |
| separate circuit breakers must be installed and separately identified (as shown in the |
| above figure). |
16
2008 RuggedCom Inc. All rights reserved | Rev104 |